Loading...
99
16.1.3 CS-PS18PKV CU-PS18PKV
Cooling Characteristic
o Room temperature: 27°C (DBT), 19°C (WBT)
o Operation condition: High fan speed
o Piping length: 5m
o Compressor Frequency = Fc
14.500
14.700
14.900
15.100
15.300
15.500
30 31 32 33 34 35 36 37 38 39 40 41 42 43
Outdoor
Temperature (°C)
Outdoor Air Temperature (°C)
220
4.500
4.700
4.900
5.100
5.300
5.500
30 31 32 33 34 35 36 37 38 39 40 41 42 43
Cooling
Capacity (kW)
Outdoor Air Temperature (°C)
6.200
6.400
6.600
6.800
7.000
7.200
7.400
7.600
7.800
8.000
8.200
30 31 32 33 34 35 36 37 38 39 40 41 42 43
Current
(A)
Outdoor Air Temperature (°C)
0.960
0.970
0.980
0.990
1.000
1.010
1.020
1.030
30 31 32 33 34 35 36 37 38 39 40 41 42 43
Gas Side Piping
Pressure (MPa)
Outdoor Air Temperature (°C)