54
• Timer Operation
When unit is turn on by ON Timer and ECONAVI & AUTO COMFORT operation is ON during previous
operation before OFF, ECONAVI & AUTO COMFORT operation will not be ON automatically.
When unit is turn on by ON Timer and ECONAVI & AUTO COMFORT operation is OFF during previous
operation before OFF, ECONAVI & AUTO COMFORT operation will not be ON automatically.
• Other Information
ECONAVI & AUTO COMFORT cannot be operated at the same time.
ECONAVI & AUTO COMFORT sensor initialized time is 70 seconds from power supplied to ECONAVI &
AUTO COMFORT sensor, or 70 seconds from the operation start.
* During low activity, fan speed 1 tap up for first 15 minutes or until set temperature is reached.
** During human absence, maximum fan speed for COOL/DRY mode is medium fan.
• ECONAVI & AUTO COMFORT Sensor abnormality check mode
• Purpose is to improve sensor serviceability when sensor is malfunction.
(1) Control starting condition
To enable infrared sensor check mode, during ECONAVI operation ON: