8
Piping
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 12.70 (1/2) 6.35 (1/4) / 15.88 (5/8)
Standard length m (ft) 5.0 (16.4) 5.0 (16.4)
Length range (min – max) m (ft) 3 (9.8) ~ 20 (65.6) 3 (9.8) ~ 20 (65.6)
I/D & O/D Height different m (ft) 15 (49.2) 15 (49.2)
Additional Gas Amount g/m (oz/ft) 15 (0.2) 20 (0.2)
Length for Additional Gas m (ft) 10 (32.8) 10 (32.8)
Drain Hose
Inner Diameter mm 16 16
Length mm 550 550
Indoor Heat
Exchanger
Fin Material Aluminium (Pre coated) Aluminium (Pre coated)
Fin Type Slit Fin Slit Fin
Row x Stage x FPI 2 x 15 x 17 2 x 15 x 17
Size (W x H x L) mm 810 x 315 x 25.4 810 x 315 x 25.4
Outdoor
Heat
Exchanger
Fin Material Aluminium (Blue coated) Aluminium (Blue coated)
Fin Type Slit Fin Slit Fin
Row x Stage x FPI 2 x 24 x 17 1 x 31 x 19
Size (W x H x L) mm 25.4 x 504 x 693.4:713.4 12.7 x 651.0 x 868.0
Air Filter
Material Polypropelene Polypropelene
Type One-touch One-touch
Power Supply Indoor Indoor
Power Supply Cord A 15 20
Thermostat - -
Protection Device - -
DRY BULB WET BULB DRY BULB WET BULB
Indoor Operation Range
Maximum °C 32 23 32 23
Minimum °C 16 11 16 11
Outdoor Operation Range
Maximum °C 43 26 43 26
Minimum °C 16 11 16 11
1. Cooling capacities are based on indoor temperature of 27°C DRY BULB (80.6°F DRY BULB), 19.0°C WET BULB (66°F WET BULB) and
outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB)