16.1.2 CS-PS12PKV CU-PS12PKV
• Cooling Characteristic
o Room temperature: 27°C (DBT), 19°C (WBT)
o Operation condition: High fan speed
o Piping length: 7.5m
o Compressor Frequency = Fc
14.500
15.000
15.500
16.000
16.500
17.000
30 31 32 33 34 35 36 37 38 39 40 41 42 43
Outdoor
Temperature (°C)
Outdoor Air Temperature (°C)
220
2.600
2.700
2.800
2.900
3.000
3.100
3.200
3.300
30 31 32 33 34 35 36 37 38 39 40 41 42 43
Cooling
Capacity (kW)
Outdoor Air Temperature (°C)
3.600
3.800
4.000
4.200
4.400
4.600
30 31 32 33 34 35 36 37 38 39 40 41 42 43
Current
(A)
Outdoor Air Temperature (°C)
1.060
1.070
1.080
1.090
1.100
1.110
30 31 32 33 34 35 36 37 38 39 40 41 42 43
Gas Side Piping
Pressure (MPa)
Outdoor Air Temperature (°C)