50
 
 
INDOOR UNIT
OUTDOOR UNIT
Product Specication
 
 
  Model
   CS-UE9PKE
 
 CU-UE9PKE
   CS-UE12PKE
 
 CU-UE12PKE
COOL
HEAT
COOL
HEAT
Single, 230V,50Hz Single, 230V,50Hz
 
Power/Current 
[kW] 0.700 0.820 1.010 1.120
[A] 3.30 3.80 4.70 5.20
    Refrigerant 
[k
g
] 0.770 0.860
  Cooling Capacity 
[kW] 2.50 3.50
   Heating Capacity 
[kW] 3.30 4.25
Noise Level 
JIS C 9612 
[<70 dB(A)]
[dB(A)]
 
42 42 42 42
Conditions 1m 
Distance 
Max. cooling/
heating 
operation 
47 48 48 50
Sound power 
level
[dB(A)]
58 58 58 58
63 64 64 66
   Air Circulation 
[m
3
/min.]  12.5 11.1 12.5 12.5
 
kg
 Product Weight
[k
g
]
 
8.0 8.0
23 26
   Dimensions (H x W x D) 
[mm]
 
290×848×213 290×848×213
540×780×289 540×780×289
•  Standby power consumption ≤ 0.9W (when switched OFF by remote control, except under self-
protection control). 
•  Standard piping length: 5m.
•  Air lters are attached. 
F568882-en.indd   50 2012-11-13   14:17:57