EasyManua.ls Logo

Panasonic CS-V7CKP - CARE AND MAINTENANCE; Cleaning the Indoor Unit and Remote Control; Cleaning the Air Filter; Cleaning the Front Panel

Panasonic CS-V7CKP
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Refrigerant Control Device Capillary Tube
Refrigeration Oil (cm
3
) FVC68D (330)
Refrigerant (R-410A) g (oz) 950 (33.5)
Thermostat Electronic Control
Protection Device 2 Stage Overload Protector
Capillary Tube Length mm 803
Flow Rate l/min 8.5
Inner Diameter mm 1.4
Air Filter Material
Style
P.P.
Honeycomb
Capacity Control Capillary Tube
Compressor Capacitor µF, VAC 30 µF, 370VAC
Fan Motor Capacitor µF, VAC 1.5 µF, 400VAC 2.0 µF, 450VAC
Specifications are subject to change without notice for further improvement.
9
CS-V7CKP CU-V7CKP5 / CS-V9CKP CU-V9CKP5 / CS-V12CKP CU-V12CKP5

Other manuals for Panasonic CS-V7CKP

Related product manuals