Cooling or Soft Dry Operation
Purpose is to obtain a comfortable room temperature while
sleeping. When you press the SLEEP Mode, the following
movement will start to avoid overcooling.
•
Sleep shift operation starts, when the room temperature
reaches the setting temperature or after 1 hour of operation.
•
The setting temperature will be risen by
0.5
°C at the start of
operation and by
0.5
°C one hour later .
•
The airflow volume will automatically change to Lo- fan
speed.
•
Sleep Mode operation time is
8
hours, the operation will be
stop after
8
hour.
•
When used together with the Timer, the Timer has priority.
Present Judgement Next Mode
Mode Cooling Soft Dry Heating
O O
Cooling 23°C Cooling (Judgement: Not Applicable (Judgement:
Heating 23°C & Above) Below 23°C)
O O
Soft Dry 23°C Soft Dry Not Applicable (Judgement: (Judgement:
Heating 23°C & Above) Below 23°C)
O O
Heating Cooling (Judgement: Not Applicable (Judgement:
23°C Heating 23°C & Above) Below 23°C)
Automatic Set Temperature
Refer 3. as below.
3. Automatic Set Temperature
For each operation, set temperature will automatically set as shown below.
However it can be selected 2°C higher or 2°C lower from standard set temperature by pressing the “Room Temperature Setting
button”.
Operation Hi (Standard) Lo
(+2°C) (±0°C) (-2°C)
Cooling 27°C 25°C 23°C
Soft Dry 24°C 22°C 20°C
Heating 23°C 21°C 19°C
•
The mode judging temperature and standard setting temperature can be increased by 2°C, by open the circuit of JX6 at
indoor electronic controller.