To remove and remount the degaussing coil:
- Unhook the coil spring from the bottom corners of the CRT
ears.
- Release the braid loop from the upper corners of the CRT ears.
7. Mount the dag ground braid on the replacement CRT. Position the
degaussing coil with new ties.
Dress coil as was on the original CRT.
8. Replace the components on CRT neck and reinstall into cabinet.
Verify that all ground wires and circuit board plugs get connected.
IMPORTANT NOTICE
When ordering the CRT, please order CRT and CRT kit also.
Please see parts list section for part numbers
9.2. Back Cover Removal