EasyManua.ls Logo

Panasonic CU-2Z50ABEC - User Manual

Panasonic CU-2Z50ABEC
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
WEB-ACXF55-35482-EN
Operating Instructions
Air Conditioner
Model No.
Indoor Unit Outdoor Unit
CS-Z20ZKEW
CS-Z25ZKEW
CS-Z35ZKEW
CS-Z42ZKEW
CS-Z50ZKEW
CS-Z71ZKEW
CS-MZ16ZKE
Single Split
CU-Z20ZKE
CU-Z25ZKE
CU-Z35ZKE
CU-Z42ZKE
CU-Z50ZKE
CU-Z71ZKE
CS-XZ20ZKEW
CS-XZ25ZKEW
CS-XZ35ZKEW
CS-XZ50ZKEW
CU-Z20ZKE
CU-Z25ZKE
CU-Z35ZKE
CU-Z50ZKE
CS-XZ20ZKEW-H
CS-XZ25ZKEW-H
CS-XZ35ZKEW-H
CS-XZ42ZKEW-H
CU-Z20ZKE
CU-Z25ZKE
CU-Z35ZKE
CU-Z42ZKE
Outdoor Unit
*Multi Split
CU-2Z35TBE
CU-2Z41TBE
CU-2Z50TBE
CU-3Z52TBE
CU-3Z68TBE
CU-4Z68TBE
CU-4Z80TBE
CU-5Z90TBE
CU-2Z50ABEC
CU-3Z75ABEC
ENGLISH
Before operating the unit, please read these operating
instructions thoroughly and keep them for future reference.
Before installation, the installer must:
Read the Installation Instructions, then request the customer
keep them for future reference.
Remove the remote control packed with the indoor unit.
* Kindly consult authorised dealer for connectivity validity.
Question and Answer IconNeed help?

Do you have a question about the Panasonic CU-2Z50ABEC and is the answer not in the manual?

Overview

This document describes the Panasonic Air Conditioner, a heat pump system designed for both single and multi-split applications, offering a range of models for various indoor and outdoor unit configurations.

Function Description:

The Panasonic Air Conditioner provides cooling, heating, and dry modes to maintain comfortable indoor temperatures. It incorporates a built-in Network Adaptor, allowing remote control via a smartphone app (Panasonic Comfort Cloud). The system is designed for individual or simultaneous operation of indoor units, with priority given to the first unit turned on. It features a "nanoe X" function for air purification, moisturization, and deodorization, and a "Powerful" mode for rapid temperature adjustment. A "Mild Dry" mode is available in single-split systems to reduce air dryness during cooling. The unit also includes an "Inside Cleaning" function to enhance internal hygiene.

Important Technical Specifications:

  • Refrigerant Type: R32 (mildly flammable). Special precautions are required for installation and servicing due to its flammability and higher working pressure compared to R22 models.
  • Operating Temperature Range:
    • COOL Mode:
      • Indoor: Max 32°C (89.6°F) DBT / 23°C (73.4°F) WBT; Min 16°C (60.8°F) DBT / 11°C (51.8°F) WBT.
      • Outdoor (Single Split): Max 43°C (109.4°F) DBT / 26°C (78.8°F) WBT; Min -10°C (14.0°F) DBT.
      • Outdoor (Multi Split *2): Max 46°C (114.8°F) DBT / 26°C (78.8°F) WBT; Min -10°C (14.0°F) DBT.
      • Outdoor (Multi Split *3): Max 46°C (114.8°F) DBT / 26°C (78.8°F) WBT; Min -10°C (14.0°F) DBT.
    • HEAT Mode:
      • Indoor: Max 30°C (86.0°F) DBT; Min 16°C (60.8°F) DBT.
      • Outdoor (Single Split): Max 24°C (75.2°F) DBT / 18°C (64.4°F) WBT; Min -20°C (-4.0°F) DBT / -21°C (-5.8°F) WBT.
      • Outdoor (Multi Split *2): Max 24°C (75.2°F) DBT / 18°C (64.4°F) WBT; Min -15°C (5.0°F) DBT / -16°C (3.2°F) WBT.
      • Outdoor (Multi Split *3): Max 24°C (75.2°F) DBT / 18°C (64.4°F) WBT; Min -25°C (-13.0°F) DBT.
  • Power Supply: Requires proper earthing and protection against electric shock (ELCB/RCD recommended).
  • Remote Control: Uses AAA or R03 batteries (x2).
  • Indoor Unit Models: CS-Z20ZKEW, CS-Z25ZKEW, CS-Z35ZKEW, CS-Z42ZKEW, CS-Z50ZKEW, CS-Z71ZKEW, CS-MZ16ZKE, CS-XZ20ZKEW, CS-XZ25ZKEW, CS-XZ35ZKEW, CS-XZ50ZKEW, CS-XZ20ZKEW-H, CS-XZ25ZKEW-H, CS-XZ35ZKEW-H, CS-XZ42ZKEW-H.
  • Outdoor Unit Models (Single Split): CU-Z20ZKE, CU-Z25ZKE, CU-Z35ZKE, CU-Z42ZKE, CU-Z50ZKE, CU-Z71ZKE.
  • Outdoor Unit Models (Multi Split): CU-2Z35TBE, CU-2Z41TBE, CU-2Z50TBE, CU-3Z52TBE, CU-3Z68TBE, CU-4Z68TBE, CU-4Z80TBE, CU-5Z90TBE, CU-2Z50ABEC, CU-3Z75ABEC.
  • Biocidal Product: Incorporates a device generating free radicals to inhibit pollutants (bacteria, viruses, mould). Active substances are generated in situ from ambient air or water. Cross-flow fan coating treated with 2-octyl-2H-isothiazol-3-one (OIT), 3-iodo-2-propynylbutylcarbamate (IPBC), and Zinc pyrithione to inhibit mold and fungi.

Usage Features:

  • Basic Operation: Start/stop with OFF/ON button, select mode (AUTO, HEAT, DRY, COOL) with MODE button, adjust temperature with TEMP UP/DOWN buttons.
  • Clock Setting: Set time using CLOCK and SET buttons on the remote control.
  • Airflow Direction: Adjustable via AIR SWING button (upper/lower and lateral direction). Manual adjustment of the flap is not recommended.
  • Fan Speed and Quiet Operation: Select fan speed (including AUTO) and "Quiet" mode for reduced noise.
  • nanoe X Function: Activates cleaner air, skin/hair moisturization, and deodorization. Can be activated when the unit is ON or OFF.
  • Powerful Mode: Quickly reaches desired temperature (stops automatically after 20 minutes).
  • Mild Dry Mode (Single Split only): Reduces air dryness during COOL mode.
  • Sleep Mode: Provides a comfortable sleeping environment by automatically adjusting temperature and dimming indoor unit indicators. Can be set with a timer.
  • Timer Function: Set ON/OFF timers for the unit at two different preset times.
  • Auto Restart Control: Restarts operation with the last mode and airflow direction after a power failure (not applicable when TIMER is set).
  • Wireless LAN Connectivity: Built-in Network Adaptor for remote control via the Panasonic Comfort Cloud app. The Wireless LAN LED can be turned off if not in use.

Maintenance Features:

  • Regular Cleaning: Essential for optimal performance and to prevent malfunctions (e.g., "H 99" error code).
  • Indoor Unit: Wipe gently with a soft damp cloth. Avoid sharp/rough items. Coils and fans should be cleaned periodically by an authorized dealer.
  • Front Panel: Wash gently and dry. Removable for cleaning.
  • Air Filters: Wash/rinse gently with water every 2 weeks. Dry thoroughly in shade. Replace damaged filters.
  • Outdoor Unit: Clean debris and ensure the drain pipe is clear.
  • Inside Cleaning Function: Activates after turning off the unit and pressing the nanoe X button for >3 seconds. Runs for up to 2.5 hours with low fan speed to clean the indoor unit. Do not turn off power during this operation.
  • Seasonal Inspection: After extended non-use, check batteries, clear obstructions, and run in COOL or HEAT mode.
  • Extended Non-Use: Activate HEAT mode for 2-3 hours to remove moisture, then turn off power, unplug, and remove remote control batteries.

Safety Precautions:

The manual emphasizes strict safety precautions due to the use of R32 refrigerant, which is mildly flammable. These include:

  • Installation: Must be performed by trained and certified personnel in a room with sufficient floor area (Amin m²). Avoid ignition sources.
  • Servicing: Only by trained and certified personnel. Ensure no refrigerant leaks, use appropriate leak detection equipment, and avoid ignition sources.
  • Electrical Safety: Do not use modified cords, share power outlets, or operate with wet hands. Ensure proper earthing and use of ELCB/RCD.
  • General Safety: Do not insert fingers into units, avoid direct exposure to cold air, do not sit/step on units.
  • Disposal: Follow national regulations for disposal of used batteries and the appliance itself.
  • Remote Control: Keep away from infants and small children to prevent battery ingestion. Do not use rechargeable (Ni-Cd) batteries.