Tube Material Copper tube
Outer Diameter mm 9.52 9.52 9.52 9.52
Thickness mm 0.3 0.3 0.3 0.3
Row 2 2 2 2
No. of Tubes/Row 34 34 46 46
Fin Material Aluminium
Thickness mm 0.105 0.105 0.105 0.105
Fin Pitch NO./
inch
14 14 14 14
Fin Surface AX-Louvre 
fin
AX-Louvre 
fin
AX-Louvre fin AX-Louvre 
fin
Total Face Area  
m
2
 
0.61 0.61 0.82 1.05
Fan Type Propeller Fan
No.of /Unit 1 1 2 2
Fan Starting Method Direct on-line Starting
Motor
Rated Output kW 0.05 0.05 0.05 x 2 0.05 x 2
Poles 6 6 6 6
Phase Single-
Phase
Single-
Phase
Single-Phase Single-
Phase
Insulation Class E E E E
15. CAPACITY AND POWER CONSUMPTION
15.1. HEATING PERFORMANCE
Model Heating capacities are based on 
conditions below.
CS-
A24BB4P 
Heating 
capacity 7.1 
kW
 
1 phase, 50Hz, 230V / Indoor 
temperature 20°C D.B. / Outdoor 
temperature 7°C D.B. 6°C W.B. / 
Standard air volume 17m
3
/min 
81