Inlet Air Outdoor Temperature (°C
W.B.)
External
Static
Pressure
(Pa) Air
Volume (m
3
/
min)
Entering
Air Dry
Bulb (°C)
-6 0 6 12
IPT IPT IPT IPT
15 2.38 2.72 3.23 3.81
27 20 2.52 2.89 3.40 3.94
25 2.65 3.06 3.57 4.07
H.C. = Heating Capacity
IPT = Power Consumption
Model Heating capacities are based on
conditions below.
CS-
A43BB4P
Heating
capacity
14.0 kW
3 phase, 50Hz, 400V / Indoor
temperature 20°C D.B. / Outdoor
temperature 7°C D.B. 6°C W.B. /
Standard air volume 30m
3
/min