Model Main Power
Compressor Motor
Indoor Unit Outdoor Unit
Source Fan Motor Fan Motor
Voltage
Frequency
S.C. R.C.(A) IPT(kW) R.C. IPT R.C. IPT
(V) (Hz) (A) COOL/
HEAT
COOL/
HEAT
(A) (kW) (A) (kW)
CS-
A24BD2P
220 50 49 10.6 / 10.5 2.31 / 2.30 1.00 0.20 0.50 0.11
CU-
A24BBP5
230 50 51 10.2 / 10.1 2.31 / 2.30 0.96 0.20 0.50 0.11
240 50 52 9.8 / 9.8 2.31 / 2.30 0.90 0.20 0.50 0.11
CS-
A28BD2P
220 50 50 11.35 /
11.05
2.49 / 2.41 1.00 0.20 0.50 0.11
CU-
A28BBP5
230 50 52 11.05 /
10.75
2.49 / 2.41 0.96 0.20 0.50 0.11
240 50 54 10.75 /
10.45
2.49 / 2.41 0.92 0.20 0.50 0.11
CS-
A28BD2P
380 50 28 4.18 / 3.98 2.49 / 2.41 1.00 0.20 0.50 0.11
CU-
A28BBP8
400 50 29 4.13 / 3.93 2.49 / 2.41 0.96 0.20 0.50 0.11
415 50 30 4.08 / 3.88 2.49 / 2.41 0.92 0.20 0.50 0.11
CS-
A34BD2P
220 50 94 15.3 / 15.1 3.23 / 3.18 2.06 0.36 1.00 0.22
CU-
A34BBP5
230 50 99 15.4 / 15.2 3.23 / 3.18 1.90 0.36 1.00 0.22
240 50 103 15.5 / 15.3 3.23 / 3.18 1.82 0.36 1.00 0.22
CS-
A34BD2P
380 50 39 5.13 / 5.23 2.93 / 3.03 2.06 0.36 1.00 0.22
CU-
400 50 41 5.13 / 5.23 2.93 / 3.03 1.90 0.36 1.00 0.22
114