Table (c): Powerful Mode Shifting
Mode: Period, X (min): Temperature Shift (°C)
E9CKP E12CKP
Cooling X 20 -2.0 -2.0
X 20 0.0 0.0
Soft Dry X 20 -1.0 -1.0
X 20 0.0 0.0
Heating X 20 +3.5 +3.5
X 20 +3.5 +3.5
Table (d): Fan Speed Shifting
Mode: Fan Speed: Temperature Shift (°C)
E9CKP E12CKP
Cooling All +1.5 +1.5
Soft Dry All +1.0 +1.0
Heating Lo +1.0 +1.0
Me-, Me, Me+, Hi, Auto +0.5 +0.5
Table (e): Start-Up Shifting
Mode within 60 Minutes from Start-up: Temperature Shift (°C)
E9CKP E12CKP
Cooling/Soft Dry -1.0 -1.0
Heating +2.0 +2.0
Table (f): Soft Dry Mode Shifting
Mode: Temperature Shift (°C)
E9CKP E12CKP
Soft Dry +1.0 +1.0