EasyManua.ls Logo

Panasonic CU-E12GKE - User Manual

Panasonic CU-E12GKE
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
© 2006 Panasonic HA Air-Conditioning (M) Sdn. Bhd.
(11969-T). All rights reserved. Unauthorized copying
and distribution is a violation of law.
Order No. MAC0611054C2
Air Conditioner
CS-E7GKEW CU-E7GKE
CS-E9GKEW CU-E9GKE
CS-E12GKEW CU-E12GKE
TABLE OF CONTENTS
PAGE PAGE
1 Safety Precaution ------------------------------------------------ 2
2 Specifications ----------------------------------------------------- 4
2.1. CS-E7GKEW CU-E7GKE ------------------------------ 4
2.2. CS-E9GKEW CU-E9GKE ------------------------------ 6
2.3. CS-E12GKEW CU-E12GKE--------------------------- 8
3Features------------------------------------------------------------10
4 Location of Controls and Components ------------------11
4.1. Product Overview-----------------------------------------11
5Dimensions--------------------------------------------------------12
5.1. Indoor Unit--------------------------------------------------12
5.2. Outdoor Unit -----------------------------------------------13
6 Refrigeration Cycle Diagram --------------------------------14
7 Block Diagram----------------------------------------------------15
8 Wiring Connection Diagram --------------------------------16
8.1. Indoor Unit--------------------------------------------------16
8.2. Outdoor Unit -----------------------------------------------17
9 Electronic Circuit Diagram -----------------------------------18
9.1. Indoor Unit ------------------------------------------------- 18
9.2. Outdoor Unit----------------------------------------------- 19
10 Printed Circuit Board ------------------------------------------ 20
10.1. Indoor Unit ------------------------------------------------- 20
10.2. Outdoor Unit----------------------------------------------- 22
11 Installation Instruction ---------------------------------------- 23
11.1. Select The Best Location ------------------------------ 23
11.2. Indoor/Outdoor Unit Installation Diagram ---------- 23
11.3. Indoor Unit ------------------------------------------------- 24
11.4. Outdoor Unit----------------------------------------------- 27
12 Operation and Control ---------------------------------------- 30
12.1. Basic Function -------------------------------------------- 30
12.2. Protection Control---------------------------------------- 40
13 Servicing Mode-------------------------------------------------- 44
13.1. Auto OFF/ON Button------------------------------------ 44
13.2. Select Remote Control Transmission Code------- 44
13.3. Remote Control Button --------------------------------- 45

Table of Contents

Questions and Answers

  • D
    David AliAug 18, 2025
    What to do if Panasonic CU-E12GKE shows total running current protection?
    • S
      Steven KramerAug 18, 2025
      If the total running current protection is triggered on your Panasonic Air Conditioner, it may occur 3 times within 20 minutes. You should check for excess refrigerant and improper heat radiation.
  • G
    Gabriel BrownAug 21, 2025
    Why does my Panasonic Air Conditioner show outdoor compressor overheating protection?
    • M
      Margaret PerezAug 21, 2025
      If your Panasonic Air Conditioner is experiencing outdoor compressor overheating protection, this might occur 4 times within 20 minutes. In such cases, check for insufficient refrigerant and the compressor itself.
  • P
    psandovalAug 23, 2025
    What to do if my Panasonic CU-E12GKE has a refrigeration cycle abnormal?
    • R
      Robert BridgesAug 23, 2025
      If your Panasonic Air Conditioner is showing a refrigeration cycle abnormality, it may occur 2 times within 20 minutes. Check for no refrigerant, ensuring the 3-way valve is not closed.
  • M
    mccarthynicholasAug 26, 2025
    What causes cool high pressure protection in Panasonic Air Conditioner?
    • R
      Robert HarrisAug 26, 2025
      If your Panasonic Air Conditioner displays a cooling high pressure protection error, it may occur 4 times within 20 minutes. Inspect the outdoor refrigerant circuit.
  • A
    April RobertsAug 28, 2025
    How to troubleshoot outdoor compressor abnormal revolution in Panasonic Air Conditioner?
    • V
      Vanessa WoodAug 28, 2025
      If your Panasonic Air Conditioner is experiencing an outdoor compressor abnormal revolution, it may happen 4 times within 20 minutes. You should check the outdoor compressor.
  • Y
    yhansenAug 30, 2025
    Why is there a cooling / heating cycle changeover abnormality in my Panasonic Air Conditioner?
    • A
      Andrea PearsonAug 30, 2025
      If your Panasonic Air Conditioner is having issues with cooling or heating cycle changeover, it may occur 4 times within 30 minutes. Check the 4-way valve and V-coil.
  • C
    Charlene WilliamsSep 1, 2025
    What to do if Panasonic CU-E12GKE Air Conditioner displays indoor fan motor mechanism lock?
    • O
      Omar GutierrezSep 1, 2025
      If the indoor fan motor mechanism is locked on your Panasonic Air Conditioner, this may occur 7 times continuously. Check the indoor PCB and fan motor.
  • L
    Lance DaviesSep 4, 2025
    How to fix outdoor Direct Current (DC) peak detection in Panasonic CU-E12GKE Air Conditioner?
    • K
      Kari HaleySep 4, 2025
      If there is an outdoor direct current peak detection issue with your Panasonic Air Conditioner, this may occur 7 times continuously. Check the outdoor PCB, IPM (Power transistor), and compressor.
  • H
    Harold SmithSep 6, 2025
    What to do if Panasonic CU-E12GKE Air Conditioner has outdoor heat exchanger temperature sensor abnormality?
    • S
      sullivanscottSep 6, 2025
      If your Panasonic Air Conditioner is showing an abnormality with the outdoor heat exchanger temperature sensor, allow it to continue for 5 seconds. Check the outdoor heat exchanger temperature sensor for defects or disconnections.
  • B
    Brian Murray DVMSep 8, 2025
    What causes outdoor air temperature sensor abnormality in Panasonic CU-E12GKE?
    • K
      Kerry BellSep 9, 2025
      If your Panasonic Air Conditioner is showing an abnormality with the outdoor air temperature sensor, allow it to continue for 5 seconds. Check the outdoor temperature sensor for defects or disconnections.

Summary

Safety Precaution

Specifications

CS-E7 GKEW CU-E7 GKE

Technical specifications for the CS-E7GKEW CU-E7GKE model.

CS-E9 GKEW CU-E9 GKE

Technical specifications for the CS-E9GKEW CU-E9GKE model.

CS-E12 GKEW CU-E12 GKE

Technical specifications for the CS-E12GKEW CU-E12GKE model.

Features

Location of Controls and Components

Product Overview

Identifies key components and controls of the indoor and outdoor units.

Dimensions

Indoor Unit

Detailed dimensions and measurement points for the indoor unit.

Outdoor Unit

Detailed dimensions and measurement points for the outdoor unit.

Refrigeration Cycle Diagram

Block Diagram

Wiring Connection Diagram

Indoor Unit

Wiring diagram for the indoor unit's electrical connections.

Outdoor Unit

Wiring diagram for the outdoor unit's electrical connections.

Electronic Circuit Diagram

Indoor Unit

Electronic circuit diagram for the indoor unit.

Outdoor Unit

Electronic circuit diagram for the outdoor unit.

Printed Circuit Board

Indoor Unit

Layout and components of the indoor unit's printed circuit boards.

Outdoor Unit

Layout and components of the outdoor unit's main printed circuit board.

Installation Instruction

Select The Best Location

Guidelines for choosing the optimal installation site for indoor and outdoor units.

Indoor;Outdoor Unit Installation Diagram

Visual guide for the physical placement and mounting of units.

Indoor Unit

Detailed procedures for installing the indoor unit.

Outdoor Unit

Detailed procedures for installing the outdoor unit.

Operation and Control

Basic Function

Explains the fundamental operating modes and inverter control.

Protection Control

Details various protection mechanisms and their triggers.

Servicing Mode

Auto OFF;ON Button

How to use the Auto OFF/ON button for special modes like Test Run.

Select Remote Control Transmission Code

Procedure for changing remote control transmission codes to prevent interference.

Remote Control Button

Explains the functions of various buttons on the remote control.

Troubleshooting Guide

Refrigeration Cycle System

Diagnosing issues based on refrigeration cycle parameters and air temperatures.

Breakdown Self Diagnosis Function

How to access and interpret error codes displayed by the unit.

Error Codes Table

A comprehensive list of error codes and their meanings.

Disassembly and Assembly Instructions

Indoor Electronic Controllers, Cross Flow Fan and Indoor Fan Motor Removal Procedures

Step-by-step guide for removing internal components of the indoor unit.

Outdoor Electronic Controller Removal Procedure

Step-by-step guide for removing the electronic controller from the outdoor unit.

Technical Data

Operation Characteristics

Performance data (capacity, current, pressure) under various operating conditions.

Sensible Capacity Chart

Charts detailing sensible capacity based on temperature conditions.

Exploded View and Replacement Parts List

Indoor Unit

Exploded view and parts list for the indoor unit.

Outdoor Unit

Exploded view and parts list for the outdoor unit.

Panasonic CU-E12GKE Specifications

General IconGeneral
Heating Capacity4.00 kW
Power Supply220-240V, 50Hz
Energy Efficiency Ratio (EER)3.21
Coefficient of Performance (COP)3.61
RefrigerantR32
Indoor Unit Weight9 kg
TypeSplit System Air Conditioner
Cooling Capacity3.5 kW
Noise Level (Indoor Unit)21 dB

Related product manuals