16
AUTO
OFF/ON
Cleaning the Air Conditioner
Cleaning has to be carried out at regular
intervals to ensure the unit is at optimal
performance. A dirty unit may cause
malfunction and you may retrieve “H 99”
error code. Consult an authorised dealer.
• Before cleaning, switch off the power supply and
unplug the unit.
• Do not touch the aluminium fi n as the sharp parts
may cause injury.
• Do not use benzine, thinner or scouring powder.
• Use soap (
pH 7) or neutral household
detergent only.
• Do not use water hotter than 40 °C / 104 °F.
Indoor unit
( Structure of the unit may vary
depending on the model)
Air fi lters
Once every 2 weeks
• Wash/rinse the fi lters gently
with water to avoid damaging
the surface.
• Dry the fi lters thoroughly under a shade, away
from fi re or direct sunlight.
• Replace any damaged fi lters.
Remove air fi lter Attach air fi lter
Remove from the unit Insert into the unit
Anti-bacterial fi lter
Anti-bacterial fi lter.
(Fitting location may
vary on models.)
• Clean the fi lter whenever necessary.
• Wash/rinse the fi lter gently with water to avoid
damage to the fi lter.
• Dry the fi lter thoroughly under the shade, away
from fi re or direct sunlight.
• Replace the fi lter every 10 years or replace any
damaged fi lter. Part no.: CZ-SA22P
Aluminium fi nFront panel
Air fi lters
Indoor unit
Wipe the unit gently with a soft
and dry cloth.
The coils and fans should be
cleaned periodically by an
authorised dealer.
Outdoor unit
Clean the debris that surround
the unit.
Clear any blockage from the drain
pipe.
Front panel
Wash gently and dry.
How to remove front panel
Raise over
horizontal
level
1
Pull upward
2
Horizontal
Close it securely
AUTO
OFF/ON
2
Match and push in
1
Hold
horizontally
3
Close down
4
Press both ends and center of the front panel
Anti-bacterial fi lter