When the Main C.B.A. is replaced, the fixed and average data must be changed by Tatsujin kit
according to the Movie Camera’s suffix.
Then, confirm and/or adjust the VTR and Camera adjustment one by one.
3.2. SERVICE EXTENSION CABLES.
This models is required the following extension cables for all connections.
Note 1:
Use the following extension cables when checking or adjusting individual circuit boards except
module Parts. (Main C.B.A.)
Ref. Part No. Pin Part Name Connection Q'ty
(1) VFK1459 39 Flat Cable FP4801 (Main) - FP4903 (Mic
Unit)
1 As
(2) VFK1582A2120 21 Flat Cable FP701(Main) - Lens Flex. 1 As
(3) VFK1595D1425 14 Flat Cable PP201(Main) - PS291 (CCD FPC) 1
(4) VFK1442 21 Flat Cable FP601(Main) - FP904 (Monitor) 1 As
(5) VFK1582A1725 17 Flat Cable FP6302(Main) - Side Case R 1
(6) VFK1582A1625 16 Flat Cable FP602(Power) - FP903(Monitor) 1 As
(7) VFK1492 26 Flat Cable FP801(Main) - FP802(EVF) 1 As
(8) VFK1595A8025 80 Flat Cable PS1001(Main) - PP1001(Power) 1
(9) VFK1582A1125 11 Flat Cable FP3403(DSC) - DSC Flex. 1
(10) VFK1365 70 Flat Cable PS301(Main) - PS3401(DSC) 1 As
How to use extension cables.
Fig. T1-1