EasyManua.ls Logo

Panasonic NN-8508 - Page 10

Panasonic NN-8508
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NN-8508,
NN-8558
NN-8808,
NN-8858
NN-8808P
DESCRIPTION
OF
OPERATING
SEQUENCE
ON,
OFF
TIME
ON
POWER
RELAY
B
ON
(SEC)
OFF
(SEC)
1.
Variable
power
cooking
control
The
coil
of
power
relay
B
(RY
B)
is
energized
intermittently
by
the
digital
programmer
circuit,
when
the
oven
is
set
at
any
power
selec-
tion
except
for
High
power
position.
The
digital
programmer
circuit
controls
the
ON-OFF
time
of
power
relay
B
contacts
in
order
to
vary
the
output
power
of
the
microwave
oven
from
“Warm”
to
“High”
power.
One
complete
ON
and
OFF
cycle
of
power
relay
B
is
22
seconds.
The
relation
between
indications
on
the
control
panel
and
the
output
of
the
microwave
oven
is
as
shown
in
Fig.
4.
NOTE:
The
ON/OFF
time
ratio
does
not
correspond
with
the
percen-
©
tage
of
microwave
power
since
approximately
1.5
seconds
are
required
for
heating
of
magnetron
filament.
2.
Cyclic
defrost
When
Defrost
power
and
defrosting
time
is
siesta
and
Start
pad
is
tapped:
(A)
The
digital
programmer
circuit
(DPC)
divides
the
total
defrosting
time
into
8
cycles
of
alternating
ON-OFF
intervals
of
defrosting
power
and
standing
periods.
(See
Fig.
5)
(B)
During
each
defrosting
period,
power
relay
B
is
energized
for
9
seconds
and
de-energized
for
13
seconds
by DPC.
(See
Fig.
6)
(C)
During
standing
periods,
power
relay
B
is
always
open
resulting
in
no
microwave
power.
Approx
Please
refer
to
description
120W
of
cyclic
defrost.
NOTE:
Defrost
time
selected
is
converted
into
seconds
by
the
DPC
but
display
will
show
selected
time
in
minutes
and
seconds
as
prog-
rammed.
The
total
number
of
seconds
is
divided
into
8
time
TOTAL
DEFROSTING
TIME
periods.
The
remainder
(seconds
not
equally
divisible
by
8)
are
i)
18
1a
vs
added
to
the
last
standing
time
period.
i
i
Example
:
if
defrosting
time
is
selected
for
5
minutes,
each
operating
period
will
be
as
follows
:
(See
Fig.
7)
5
minutes
=
300
seconds
300/8
=
37
and
remainder
is
4
seconds.
The
4
seconds
is
added
to
the
last
time
period.
NOTE:
When
defrosting
time
is
selected
for
not
more
than
7
seconds,
the
power
relay
B
will
not
be
energized
at
all.
OUTPUT
POWER
INDICATION
|
AGAINST
HIGH
POWER
mete
ao
Fig.
5
ONE
DEFROSTING
PERIOO(T/8)
aT
Fig.
6
S5MIN_(300SEC)
tsT
2ND
2ND
LAST
STANDING(
37S)
,DEFROSTING(373)
STANDING(373)
STANDING(
443)
Fig.
7

Related product manuals