NN-8508,
NN-8558
NN-8808,
NN-8858
NN-8808P
-DISASSEMBLY
AND
PARTS
REPLACEMENT
PROCEDURE
1.
Replacement
of
the
magnetron
CAUTION
Servicemen
should
remove
their
watches
whenever
working
close
to
or
replacing
the
magnetron.
(A)
Discharge
the
high
voltage
capacitor.
(See
page
15)
(B)
Remove
2
screws
holding
air
guide
A.
(Fig.
16)
(C)
Remove
2
high
voltage
leads
from
filament
terminals.
(F,
FA)
(D)
Remove
4
screws
holding
the
magnetron.
(Fig.
16)
NOTE:
To
prevent
microwave
leakage,
tighten
mounting
screws
proper-
ly
making
sure
there
is
no
gap
between
the
waveguide
and
the
magnetron.
CAUTION
When
connecting
2
filament
lead
wires
to
the
mag-
netron
terminals,
be
sure
to
connect
the
lead
wires
in
the
correct
position.
The
lead
wire
of
high
voltage
transformer
should
be
connected
to
“F
terminal”
and
the
lead
wire
from
high
voltage
capacitor
should
be
connected
to
“FA
terminal”.
(See
Fig.
16)
2.
citor.
(A)
Disconnect
2
lead
wires
from
fan
motor
terminals.
(Fig.
17)
(B)
Disconnect
2
lead
wires
from
fuse
holder
terminals.
(Fig.
17)
(C)
Disconnect
4
high
voltage
lead
wires
from
high
voltage
capacitor
ter-
minals.
(Fig.
17)
(D)
Remove
4
screws
holding
fan
motor
and
orifice
assy
and
detach
the
orifice
assy
with
fan
motor
from
oven
assy.
(Fig.
18)
(E)
Remove
fan
blade
from
the
fan
motor
shaft
by
pulling
it
straight
out.
(F)
Separate
the
fan
motor
from
the
orifice
assy
by
freeing
2
catch
hooks
on
the
orifice
assy.
To
replace
high
voltage
capacitor
(G)
Remove
1
screw
holding
high
voltage
capacitor.
Replacement
of
the fan
motor
and
high
voltage
capa-
AIR
GUIDE
A
THERMAL
CUTOUT
MAGNE
TRON
roe
/
C$
—\—
9
arp
te
my]
|
——
=s
Of
j
Fig.
16
FAN
MOTOR
TERMINALS
15A
FUSE
HIGH
VOLTAGE
CAPACITOR
Fig.
17
Fig.
18

Related product manuals