Loading...
NN-8508,
NN~8558
NN-8808,
NN-8858
NN-8808P
{TROUBLE
2]
Fuse
is
blown.
Replace
fuse
Plug
power
cable
into
wall
receptacle
and
open
door
N
2
Is
fuse
blown?
=
For
U.S.A.
For
Canadian
models
models
No
continuity
Check
continuity
of
Continuity
Check
continuity
of
Check
continuity
of
short
switch
latch
switch
A
and
latch
switch
A
power
relay
B(RY
B)
Continuity
Continuity
Disconnect
one
side
of
lead
wire
connected
between
H.V.T.
and
H.V.C.
and
operate
unit
Normal
Defective
H.V.C.
Fuse
blows
Defective
H.V.T.
Shorted
contacts
of
short
switch
Replace
latch
switch
A
and
short
switch
(NOTE
1
and
2)
NOTE
1:
All
these
switches
must
be
replaced
at
same
time.
(Refer
to
page
23
for
adjustment
instructions.
)
NOTE
2:
Check
continuity
of
power
relay
B's
contacts
(between
1
and
2)
and
if
it
has
continuity,
replace
power
relay
B
too.
Shorted
contacts
of
latch
switch
A
and
power
relay
B
(RY
B)
Shorted
latch
switch
A
Replace
latch
switch
A,
short
switch
and
power
relay
8B
(NOTE
1
and
2)
Replace
latch
switch
A
and
short
switch
(NOTE
1)
{TROUBLE
3]
Microwave
cooking
program
works
normally,
but
bake
and/or
broil
cooking
programs
do
not.
Lower
heater
does
not
heat
up.
Check
continuity
No
continuity
of
lower
heater
Which
heater
does
nok
hast
up'at
all?
Upper
heater
does
not
heat
up.
Open
lower
heater
Normal
Approx:
102
Check
continuity
of
upper
heater
Normal
:
Approx:102
No
continuity
Check
power
relay
Abnormal
N
Check
power
relay
D
(RY
D)
a
C
(RY
C)
Open
upper
heater
Normal
Abnormal
Defective
power
relay
D
(RY
D)
Defective
D.P.C.
See
“TROUBLE
5"
Defective
D.P.C.
See
“TROUBLE
5"
Defective
power
relay
C
(RY
C)

Related product manuals