D. REMOVING MAGNETRON
(Figures 11 Through 13)
(1) Remove vent grille.
(2) Remove mount.
(3) Remove outer case.
(4) Disconnect the wireleads.
(5) Remove the Magnetron very carefully.
NOTES:
• When removing the magnetron, make sure that its
dome does not hit any adjacent parts, or it may be
damaged.
• When replacing the magnetron, be sure to install the
magnetron gasket in the correct position and be sure
that the gasket is in good condition.
• After replacing the magnetron, check for microwave
energy leakage with a survey meter. Microwave
energy leakage must be below the limit of 5
mW/cm
2
. (All service adjustments should be made
for minimum microwave energy leakage readings.)
7-8