6. Insert the capillary tube at least 1 cm inside the new dryer
and weld the connection.
Note: Dryer must be changed in every time before
gas charging.
7. Curl the capillary tube as in the below picture. Weld the
main tube and new service tube to dryer.
8. Change the service pipe of compressor with new one.