NR-BW414 / NR-BW464
- 7 -
4.1 Protection for IC
1
Does IC receive IPM protect signal?
2
IC orders to stop compressor for 10 min.
3
After 10 min, does PCB check if IPM protect signal
is normal?
4
IC cancels to stop compressor. Normal operating.
5
After restarting, does “Stop compressor” occure 10
times within 2 min?
6
IC cancels to stop compressor. Normal operating.
8
Does system protection cycle for 333 times?
9
IC orders to stop compressor completely.
YES
YES
NO
YES
• Normal operating.
• IC continues to stop compressor until 1 hour.
• IC indicates Self diagnosing sign.
NO
NO
YES
7
After 1 hour.
SYSTEM PROTECT CONTROL CYCLE
1
st
time
OPERATE each 7min X 10 times
COMPRESSOR 1hour STOP
OPERATE each 7min X 10 times
SYSTEM PROTECT CONTROL CYCLE
333
rd
time
STOP COMPRESSOR
• IC continues to stop compressor until 1 hour.
• IC indicates Self diagnosing sign.
4. SELF PROTECTING FUNCTION