This system has been tested according to NSF/ANSI 42, 53, 401 for reduction of the
substances listed below. The concentration of the indicated substances in water entering the
system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specied in NSF/ANSI 42, 53, 401.
Substance
Influent Challenge
Concentration
Average
Reduction
Reduction
Requirement
Max Permissible Product
Water Concentration
Cholorince, Taste & Odor
2.0 mg/ L ± 10% 97.5% ≥ 50% N/A
Particulate, Class 1
>0.5μm to <1μm
At least 10,000
particles/ ml
99.7% ≥ 85% N/A
Asbestos 10
7
to 10
8
bers/ L > 99% 99% N/A
Cyst Min. 50,000 cysts/ L > 99.99% 99.95% N/A
Lead pH 6.5 0.15 mg/ L ± 10% 99.3% N/A 0.005 mg/ L
Lead pH 8.5 0.15 mg/ L ± 10% > 99.3% N/A 0.005 mg/ L
Mercury pH 6.5 0.006 mg/ L ± 10% 96.6% N/A 0.002 mg/ L
Mercury pH 8.5 0.006 mg/ L ± 10% 95.9% N/A 0.002 mg/ L
O-Dichlorobenzene
1.8 m
g
/ L ± 10%
> 99.9% N/A 0.6 mg/ L
± 10%
Carbofuran 0.08 mg/ L ± 10% 98.7% N/A 0.04 mg/ L
Benzene 0.015 mg/ L ± 10% > 97.0% N/A 0.005 mg/ L
Atrazine 0.009 mg/ L ± 10% > 94.8% N/A 0.003 mg/ L
Turbidity 11 ± 1 NTU 99.1% N/A 0.5 NTU
Toxaphence 0.015 mg/ L ± 10% > 93.8% N/A 0.003 mg/ L
Operation Conditions
Capacity 1,136 L (300 gal)
Function Chemical / Mechanical
Usage Life 6 months
Flow Rate 1.9 lpm (0.5 gpm)
Temperature 2 ~ 38 °C (35 ~ 100 °F)
Pressure 206 ~ 861 kPa (30 ~ 125 psi)
System model: ARBHBA300020
Replacement Cartridge: ARAHFA105010
EPA Number: EPA Est No.94813-KOR-1
(NSF/ANSI Standard 53 Certied to reduce Cyst
by mechanical means.)
Manufactured by Microlter Co.,Ltd.
162-1, Sansu, Deoksan, Jincheon, Chung-Buk
27856, Korea.
Made in Korea
Tel no.: T: 82-43-531-7021~5 /F: 82-43-530-5499
Remark
Systems must be installed and operated in accordance with manufacturer's recommended
procedures and guidelines. Follow any and all local plumbing codes and requirements.
Some local codes may require the use of a licensed plumber or a certied installer when
disrupting a potable water line.
Failure to follow instructions may result in voidance of warranty.
Change the filter cartridge at least every 6 months.
To reduce the risks associated with water leakage, which, if not avoided, may result in
property damage - check with your plumbing professional to verify that water pressure is
less than 827 kPa (120 psi).
Performance Data Sheet For Filter System Model: ARBHBA300020
System tested and certied by NSF International against NSF/ANSI
Standards 42, 53, 401 in System Model ARBHBA300020 for reduction
claims specied on the Performance Data Sheet.
54

Related product manuals