file:///E:/PV-9661_PV-9662/SVC/s0603030000.html
6.3.3 PG SHIFTER ADJUSTMENT
TOP PREVIOUS NEXT 
●     Purpose:
Determine the Video Head Switching Point during Playback.
●     Symptom of Misadjustment:
May cause Head Switching Noise and/or Vertical Jitter.
●     Test Point:
TP3001 (Main C.B.A.)
TP6205 (Main C.B.A.)
●     Adjustment:
R6201 (Main C.B.A.)
●     Specification:
T = 6 +/- 1H (0.38 +/- 0.06msec.)
●     Mode:
SP Playback
●     Equipment:
Oscilloscope,
VHS Alignment Tape (VFMS0003H6)
1.  Connect the channel-1 scope probe to TP3001 and the channel-2 scope probe to TP6205. 
Trigger from channel-2.
2.  Playback the VHS alignment tape, and then connect TP6003 to GND to be in PG Shifter 
Adjustment mode.