1. Dual-Trace Oscilloscope
Voltage Range: 0.001 V to 50 V/Div.
Frequency Range: DC to 50 MHz
Probes: 10:1, 1:1
2. Isolation Transformer (Variable)
3. VHS Alignment Tape (VFMS0003H6)
4. TV monitor
6.3.3. HOW TO READ THE ADJUSTMENT PROCEDURES
Fig.E1
6.3.4. PG SHIFTER ADJUSTMENT
Purpose:
Determine the Video Head Switching Point during Playback.
Symptom of Misadjustment:
May cause Head Switching Noise and/or Vertical Jitter.
Test Point :
TP3001 (Main C.B.A.),
TP6205 (Main C.B.A.)
Specification:
T = 6 H±0.5 H (0.38 ms±0.03 ms)
Mode :
SP Playback
45