Operating Instructions
Split System Air Conditioner
Model No.
This air conditioner uses the refrigerant R410A.
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
Indoor Unit
26 36
Nominal Capacity
F2 Low Silhouette Ducted
S-26PF2U6
26 36
S-36PF2U6
Indoor Unit Type
Type
Outdoor Unit
Nominal Capacity
U Single
Outdoor Unit Type
Type
U-36PE1U6 Cooling/HeatingU-26PE1U6
Remarks
z Connectable outdoor unit lineup
This booklet is the operating instructions for indoor unit. Regarding the outdoor unit, see the operating
instructions supplied with the outdoor unit.

Other manuals for Panasonic S-36PF2U6

Questions and Answers

  • D
    Darryl CobbAug 7, 2025
    Why is my Panasonic S-36PF2U6 making noise?
    • J
      Jonathan MorganAug 7, 2025
      The noise could be due to several reasons: * The sound of refrigerant liquid flowing inside the unit. You might hear a streaming water sound during or after operation. * The sound of drainage water flowing through the drain pipe. This also sounds like streaming water during or after operation. * Cracking sounds may occur due to temperature changes of parts during operation or when the unit stops.
  • R
    Robert VillaAug 11, 2025
    Why does my Panasonic S-36PF2U6 smell?
    • R
      Robin MorrisonAug 12, 2025
      The odor could be due to indoor odor components, such as cigarette smoke or cosmetic odors, accumulated in the air conditioner. This causes discharged air to smell during operation. If the unit inside is dusty, consult your dealer.
  • C
    colealexanderAug 16, 2025
    What to do if my Panasonic S-36PF2U6 Air Conditioner is producing fog?
    • K
      Kayla MoonAug 16, 2025
      Fog may occur because the unit inside (heat exchanger) is dirty, in which case cleaning is necessary. Consult your dealer, as technical engineering is required. Fog can also occur during defrost operation, especially during cooling mode.
  • J
    Jennifer SanchezAug 22, 2025
    Why is my Panasonic S-36PF2U6 Air Conditioner fan still running after I turn it off?
    • C
      Chad OliverAug 22, 2025
      The fan may continue to rotate after the operation stops to ensure smooth operation or to dry the heat exchanger due to specific settings. This is normal.
  • J
    Jonathan GriffinAug 27, 2025
    Why is my Panasonic S-36PF2U6 Air Conditioner making noise in heating mode?
    • B
      Beverly McdonaldAug 27, 2025
      Noise often occurs during defrost operation in heating mode.
  • D
    Douglas MccallSep 1, 2025
    Why is my Panasonic S-36PF2U6 outdoor unit fan still running after stopping it with the remote?
    • E
      Erin AyersSep 1, 2025
      The fan may continue to rotate to ensure smooth operation. Check operation after stopping by remote controller; this is normal.

Summary

Alert Symbols

Installation Location

Electrical Requirements

Safety Instructions

Operation Condition

Care and Cleaning

Indoor Unit Cleaning

Instructions for cleaning air intake, outlet, and internal components.

Troubleshooting

Indoor Unit Troubleshooting

Diagnosing and resolving noise, odor, dewdrop, fog, and dust issues.

Outdoor Unit Troubleshooting

Resolving issues like no operation, noise, and steam in the outdoor unit.

Check Before Requiring Services

Tips for Energy Saving

Specifications

Panasonic S-36PF2U6 Specifications

General IconGeneral
RefrigerantR410A
Cooling Capacity36000 BTU
SEER Rating16 SEER
HSPF Rating9.0
Voltage208/230V
Seasonal Energy Efficiency Ratio (SEER)16 SEER
Heating Seasonal Performance Factor (HSPF)9.0
Power Supply208/230V, 1 Phase, 60Hz
Operating Temperature (Cooling)64°F to 90°F
Operating Temperature (Heating)5°F to 75°F

Related product manuals