1-160
1
Single -Type
1-1. Unit Specifi cations
PEY1
2. Ceiling Type S-125PT2E5A / U-125PEY1E5
INDOOR MODEL S-125PT2E5A
PANEL MODEL
OUTDOOR MODEL U-125PEY1E5
Branch pipe MODEL -
PERFORMANCE TEST CONDITION ISO5151 / EN14511 / EN12102
POWER SUPPLY
ø, Hz 1ø 50Hz 1ø 50Hz
V 220 230 240 220 230 240 Min Max
C
O
O
L
I
N
G
CAPACITY
kW 12.5 12.5 12.5 3.8 13.5
BTU/h 42700 42700 42700 13000 46100
CURRENT A 0.89 0.86 0.83 19.7 18.9 18.1 - -
INPUT POWER
W 110 110 110 4.040k 4.040k 4.040k - -
TOTAL W - 4.150k 4.150k 4.150k 900 5.160k
ANNUAL CONSUMPTION
TOTAL kWh
*
4 - - 2075 - - -
EER/EER CLASS
TOTAL(W/W)
*
5/("A"~"G")
- - - 3.01 3.01 / B 3.01 4.22 2.62
Erp
*
6
Pdsign kW - - - - - -
SEER (W/W) - - - - - -
Annual consumption
kWh------
Class - - - - - -
POWER FACTOR % - - - 93 93 93 - -
NOISE INDOOR
(H/M/L)
dB-A 46/40/36 -
Power Level dB 64/58/54 -
NOISE OUTDOOR
(H/L)
dB-A 56/-
Power Level dB 73/-
H
E
A
T
I
N
G
CAPACITY
kW 12.5 12.5 12.5 3.4 15.0
BTU/h 42700 42700 42700 11600 51200
CURRENT A 0.89 0.86 0.83 15.2 14.6 13.9 - -
INPUT POWER
W 110 110 110 3.140k 3.140k 3.140k - -
TOTAL W - 3.250k 3.250k 3.250k 730 4.400k
COP/COP CLASS
TOTAL(W/W)
*
5/("A"~"G")
- - - 3.85 3.85 / A 3.85 4.66 3.41
Erp
*
6
Pdsign kW - - - - - -
Tbivalen °C - - - - - -
SCOP (W/W) - - - - - -
Annual consumption
kWh------
Class - - - - - -
POWER FACTOR % - - - 94 94 94 - -
NOISE INDOOR
(H/M/L)
dB-A 46/40/36 - ⁄ ⁄
Power Level dB 64/58/54 -
NOISE OUTDOOR
(H/L)
dB-A - 56/- ⁄ ⁄
Power Level dB - 73/-
EXTRA LOW TEMP
Total CAPACITY(kW)/INPUT POWER(W)/COP
-
MAX CURRENT(A)/MAX INPUT POWER(W) 0.89/110 0.86/110 0.83/110 29.0/5.93k 29.0/6.20k 29.0/6.47k ⁄
STARTING CURRENT(A)/COMP OUTPUT(W) - - - 19.7/3.0k 18.9/3.0k 18.1/3.0k⁄
NETWORK IMPEDANCE (ΩMAX.) - -
FM OUTPUT (W) 111 90 ⁄
MOISTURE REMOVAL VOLUME L/h(Pt/h) 7.9 (16.6) -
External static pressure
Pa
-
I/D AIR
FLOW
COOL m
3
/min (ft
3
/min) 34/28/24 (1201/989/848)
HEAT m
3
/min (ft
3
/min) 34/28/24 (1201/989/848)
O/D AIR
FLOW
COOL m
3
/min (ft
3
/min) 80 (2825)
HEAT m
3
/min (ft
3
/min) 73 (2578)
REFRIGERANT TYPE, AMOUNT
g
(oz) R410A 3.20k (112.9) /
P
R
O
D
I
M
HEIGHT : H mm(inch) 235 (9-1/4) 996 (39-7/32) /
WIDTH : W mm(inch) 1590 (62-19/32) 940 (37-1/32) /
DEPTH : D mm(inch) 690 (27-5/32) 340 (13-13/32) /
P
A
C
D
I
M
HEIGHT : H mm 360 1136 /
WIDTH : W mm 1655 1055 /
DEPTH : D mm 820 485 /
MASS
(NET) k
g
(lb) 40 (88) 85 (187) /
(GROSS) k
g
(lb) 49 (108) 93 (205) /
LAYERS LIMIT (actually) 9 (10) 2 (3)
Operation
Condition
Cool O.D(DBT) 18°C ~ 32°C -10°C ~ 43°C
Heat O.D(DBT) 16°C ~ 30°C -15°C ~ 24°C
P
I
P
I
N
G
PIPE DIAMETER mm (inch)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8) (Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
CONNECT METHOD, STD LENGTH m (ft)
fl ared type, 5.0(16.4) fl ared type, 5.0(16.4)
PIPE LENGTH RANGE m (ft)
5 ~ 50 (16.4 ~ 164.0) ~ ~
I/D&O/D HEIGHT DIFFERENCE m (ft)
15 (OD located lower) / 30 (OD located higher) (49.2/98.4)
ADD GAS AMOUNT
g
/m (oz/ft)
50 (0.538)
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
30 (98.4)
*1
:
In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
*2
:
If the EUROVENT Certifi ed models can be operated under the “extra-low” temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3
:
Network Impedance shall be applicable for EUROPE and CHINA models.
*4
:
The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5
:
EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
SM830231-02Single欧州.indb160SM830231-02Single欧州.indb160 2014/09/1913:21:162014/09/1913:21:16