Operating Instructions
Air Conditioner
ENGLISH
Before operating the unit, read these operating instructions thoroughly and
keep them for future reference.
Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan
WEB-ACXF55-28600-EN
4-Way Cassette 60 × 60
(Type Y3)
Model No.
INDOOR UNIT
4-Way Cassette 60 × 60
(Type Y3)
S-M20PY3E
S-25PY3E
S-36PY3E
S-50PY3E
S-60PY3E
OUTDOOR UNIT
Single Split
See page 12.
RAC Multi
See page 19 (Supplement).
OI_00_331027_EN.indb 1 2021/9/1 13:03:17

Other manuals for Panasonic S-50PY3E

Questions and Answers

  • N
    Nicholas BrownAug 12, 2025
    Why is my Panasonic S-50PY3E Air Conditioner not cooling or heating properly?
    • S
      Scott CaseyAug 13, 2025
      If your Panasonic Air Conditioner's cooling or heating performance is poor, it might be due to the indoor unit's sensor being improperly positioned. The built-in sensor may sense temperature improperly, for example, temperature difference between the ceiling and floor, lighting apparatus, electric fan, windows or waist-high partition walls, etc.. Consult your dealer about changing the temperature sensor setting to use the remote controller's sensor instead. Also, minimize heat sources in the room and reduce the number of people in the room.
  • M
    michaelgardnerAug 16, 2025
    Why is my Panasonic S-50PY3E performing poorly in cooling or heating?
    • T
      Timothy HaasAug 16, 2025
      If your Panasonic Air Conditioner isn't cooling or heating well, check if the air intake or air discharge port of the indoor and outdoor units are blocked by dust or obstacles. If so, remove the dust or obstructions to improve performance. Also check the fan speed and change it to 'Medium' or 'High' if it is set to 'Low'.
  • K
    Kathryn OrtizAug 20, 2025
    What to do if Panasonic S-50PY3E Air Conditioner does not run when turned on?
    • C
      Chloe McclureAug 20, 2025
      If your Panasonic Air Conditioner isn't running even when powered on, first, press the ON/OFF operation button on the remote controller again, especially if there was a recent power failure. If the operation button is turned off, switch on the power. If the breaker has been tripped, consult your dealer without turning it on. If the fuse is blown, consult your dealer.
  • C
    Cheryl HendrixAug 25, 2025
    Why is my Panasonic S-50PY3E Air Conditioner making noise?
    • J
      John DavisAug 25, 2025
      The noise you hear from your Panasonic Air Conditioner could be the sound of refrigerant liquid flowing inside the unit or the sound of drainage water through the drain pipe. It may also be a cracking sound caused by temperature changes of parts.
  • M
    martinmarkAug 27, 2025
    Why is my Panasonic S-50PY3E Air Conditioner emitting fog?
    • K
      Kathleen StevensAug 27, 2025
      Fog coming from your Panasonic Air Conditioner could be due to a dirty heat exchanger inside the unit, requiring cleaning. It is recommended to consult your dealer, as technical engineering is required. Fog can also appear during defrost operation.
  • G
    Gregory WallaceAug 31, 2025
    Why is my Panasonic Air Conditioner discharging dust?
    • K
      Kevin BradyAug 31, 2025
      Dust discharge may occur if dust has accumulated inside the indoor unit. Ensure that nanoe™ X is set to ON. If nanoe™ X is already ON, it may be considered abnormal, and you should contact your dealer.
  • S
    steven54Sep 4, 2025
    What to do if my Panasonic S-50PY3E smells bad?
    • B
      Brenda HermanSep 4, 2025
      The unit inside is dirty and has accumulated odor components. Contact your dealer for assistance.
  • M
    melissawheelerSep 7, 2025
    Why is my Panasonic S-50PY3E Air Conditioner making noise during heating?
    • K
      Krystal ThompsonSep 7, 2025
      The noise you are hearing during heating operation is likely due to the defrost operation being in process.

Summary

Precautions for Use

Maintenance

Troubleshooting

Indoor Unit Issues

Common symptoms and causes for problems related to the indoor unit.

Outdoor Unit Issues

Common symptoms and causes for problems related to the outdoor unit.

Before Requesting Services

Unit Not Operating

Checks and actions for when the unit does not operate after power is turned on.

Poor Performance Issues

Checks and actions for poor cooling or heating performance.

Indoor Unit Specifications

4-Way Cassette 60 x 60 (Type Y3)

Detailed specifications for the 4-Way Cassette 60 x 60 (Type Y3) indoor unit models.

Outdoor Unit Specifications (Europe)

Single Split Outdoor Unit (R32) - Europe

Specifications for European Single Split Outdoor Units (R32) models.

Outdoor Unit Specifications (Oceania)

Single Split Outdoor Unit (R32) - Oceania

Specifications for Oceania Single Split Outdoor Units (R32) models.

Supplement: Multi Split Indoor Unit Specs

Supplement: Multi Split Outdoor Unit Specs

Overview

This document provides operating instructions for the Panasonic 4-Way Cassette 60 x 60 (Type Y3) air conditioner, including both indoor and outdoor units, as well as multi-split systems.

Function Description

The Panasonic 4-Way Cassette 60 x 60 (Type Y3) is a commercial air conditioner indoor unit designed to provide comfortable room conditions. It incorporates a biocidal product that generates ionized air to deactivate bacteria and viruses in the air and on surfaces, and inhibits mold growth. The active substances are free radicals generated in situ from ambient air or water. The unit is designed for use in shops, light industry, farms, or commercial settings by expert or trained users.

The air conditioner features a nanoe™ X Function for a fresher and cleaner environment. This function generates negative ions to improve air quality, reduce odors, and constrain the propagation of mold and bacteria. The nanoe™ X function operates automatically upon purchase, but can be set to OFF via the remote controller.

An Internal Cleaning Function is activated when cooling or dry operation stops. This function performs internal drying and nanoe™ X circulation airflow to suppress mold proliferation inside the unit (airflow passage, fan, heat exchanger). The duration of this operation is up to 75 minutes. The effectiveness of mold proliferation inhibition may vary depending on the installation environment or operating hours.

Important Technical Specifications

Indoor Unit (4-Way Cassette 60 x 60, Type Y3)

  • Model Numbers: S-M20PY3E, S-25PY3E, S-36PY3E, S-50PY3E, S-60PY3E
  • Power Source (Europe): 220-230-240 V~ 50 Hz
  • Power Source (Oceania): 230-240 V~ 50 Hz
  • Cooling Capacity:
    • S-25PY3E: 2.5 kW (8,500 BTU/h)
    • S-36PY3E: 3.6 kW (12,300 BTU/h)
    • S-50PY3E: 5.0 kW (17,100 BTU/h)
    • S-60PY3E: 6.0 kW (20,500 BTU/h)
  • Heating Capacity:
    • S-25PY3E: 3.2 kW (10,900 BTU/h)
    • S-36PY3E: 3.6 kW (12,300 BTU/h)
    • S-50PY3E: 5.0 kW (17,100 BTU/h)
    • S-60PY3E: 6.0 kW (20,500 BTU/h)
  • Cooling Electric Power Input (nanoe™ X OFF):
    • S-25PY3E: -
    • S-36PY3E: 0.021 kW
    • S-50PY3E: 0.034 kW
    • S-60PY3E: 0.048 kW
  • Heating Electric Power Input (nanoe™ X OFF):
    • S-25PY3E: -
    • S-36PY3E: 0.019 kW
    • S-50PY3E: 0.032 kW
    • S-60PY3E: 0.046 kW
  • Sound Pressure Level (Cooling/Heating):
    • S-25PY3E: High 31/33 dB(A), Medium 28/28 dB(A), Low 25/25 dB(A)
    • S-36PY3E: High 34/34 dB(A), Medium 30/30 dB(A), Low 25/25 dB(A)
    • S-50PY3E: High 39/39 dB(A), Medium 34/34 dB(A), Low 27/27 dB(A)
    • S-60PY3E: High 43/43 dB(A), Medium 37/37 dB(A), Low 31/31 dB(A)
  • Sound Power Level (Cooling/Heating):
    • S-25PY3E: High 46/46 dB(A), Medium 43/43 dB(A), Low 40/40 dB(A)
    • S-36PY3E: High 49/49 dB(A), Medium 45/45 dB(A), Low 40/40 dB(A)
    • S-50PY3E: High 54/54 dB(A), Medium 49/49 dB(A), Low 42/42 dB(A)
    • S-60PY3E: High 58/58 dB(A), Medium 52/52 dB(A), Low 46/46 dB(A)
  • Unit Dimensions (H×W×D): 273×625×625 mm
  • Net Weight: 17.8 kg
  • Operation Condition Temperature Range:
    • Cooling mode: 18°C~32°C DB
    • Heating mode: 16°C~30°C DB

Outdoor Unit (Single Split, R32 Refrigerant)

  • PZH2 Series (Europe):
    • Models: U-36PZH2E5, U-50PZH2E5, U-71PZH2E5/E8, U-100PZH2E5/E8, U-125PZH2E5/E8, U-140PZH2E5/E8
    • Power Source: 220-230-240 V~ 50 Hz (1-phase), 380-400-415 V 3N~ 50 Hz (3-phase)
    • Cooling Capacity: 3.6 kW to 14.0 kW
    • Heating Capacity: 4.0 kW to 16.0 kW
    • Sound Pressure Level (Cooling/Heating): 43/44 dB(A) to 54/54 dB(A)
    • Sound Power Level (Cooling/Heating): 62/64 dB(A) to 71/71 dB(A)
    • Unit Dimensions (H×W×D): 695×875×320 mm to 1,416×940×340 mm
    • Net Weight: 43 kg to 99 kg
    • Operation Condition Temperature Range: Cooling -15°C~46°C DB (some models -20°C), Heating -20°C~24°C DB
  • PZ2 Series (Europe):
    • Models: U-100PZ2E5/E8
    • Power Source: 220-230-240 V~ 50 Hz (1-phase), 380-400-415 V 3N~ 50 Hz (3-phase)
    • Cooling Capacity: 10.0 kW
    • Heating Capacity: 10.0 kW
    • Sound Pressure Level (Cooling/Heating): 52/52 dB(A)
    • Sound Power Level (Cooling/Heating): 70/70 dB(A)
    • Unit Dimensions (H×W×D): 996×980×370 mm
    • Net Weight: 90 kg
    • Operation Condition Temperature Range: Cooling -10°C~43°C DB, Heating -15°C~24°C DB
  • PZH3 Series (Europe):
    • Models: U-36PZH3E5, U-50PZH3E5, U-60PZH3E5, U-71PZH3E5/E8, U-100PZH3E5/E8, U-125PZH3E5/E8, U-140PZH3E5/E8
    • Power Source: 220-230-240 V~ 50 Hz (1-phase), 380-400-415 V 3N~ 50 Hz (3-phase)
    • Cooling Capacity: 3.6 kW to 14.0 kW
    • Heating Capacity: 4.0 kW to 16.0 kW
    • Sound Pressure Level (Cooling/Heating): 43/44 dB(A) to 54/54 dB(A)
    • Sound Power Level (Cooling/Heating): 62/64 dB(A) to 71/71 dB(A)
    • Unit Dimensions (H×W×D): 695×875×320 mm to 1,416×940×340 mm
    • Net Weight: 42 kg to 98 kg
    • Operation Condition Temperature Range: Cooling -15°C~48°C DB, Heating -20°C~24°C DB
  • PZ3 Series (Europe):
    • Models: U-25PZ3E5, U-36PZ3E5, U-50PZ3E5, U-60PZ3E5A, U-100PZ3E5/E8, U-125PZ3E5/E8
    • Power Source: 220-230-240 V~ 50 Hz (1-phase), 380-400-415 V 3N~ 50 Hz (3-phase)
    • Cooling Capacity: 2.5 kW to 12.5 kW
    • Heating Capacity: 3.2 kW to 12.5 kW
    • Sound Pressure Level (Cooling/Heating): 46/47 dB(A) to 55/55 dB(A)
    • Sound Power Level (Cooling/Heating): 64/66 dB(A) to 73/73 dB(A)
    • Unit Dimensions (H×W×D): 619×824×299 mm to 996×980×370 mm
    • Net Weight: 32 kg to 87 kg
    • Operation Condition Temperature Range: Cooling -10°C~43°C DB, Heating -15°C~24°C DB
  • PZ3 Series (Oceania):
    • Models: U-25PZ3R5, U-36PZ3R5, U-50PZ3R5, U-60PZ3R5
    • Power Source: 230-240 V~ 50 Hz
    • Cooling Capacity: 2.5 kW to 6.0 kW
    • Heating Capacity: 3.2 kW to 6.0 kW
    • Sound Pressure Level (Cooling/Heating): 48/49 dB(A)
    • Sound Power Level (Cooling/Heating): 66/67 dB(A)
    • Unit Dimensions (H×W×D): 619×824×299 mm to 695×875×320 mm
    • Net Weight: 31 kg to 43 kg
    • Operation Condition Temperature Range: Cooling -10°C~43°C DB, Heating -15°C~24°C DB

RAC Multi Outdoor Unit (R32 Refrigerant)

  • 2 Room Multi (Type 35, 41, 50):
    • Models: CU-2Z35TBE, CU-2Z41TBE, CU-2Z50TBE
    • Power Source: Single phase, 230 V, 50 Hz
    • Cooling Capacity: 3.50 kW to 5.00 kW
    • Heating Capacity: 4.20 kW to 5.60 kW
    • Sound Pressure Level (Cooling/Heating): 48/50 dB(A) to 50/52 dB(A)
    • Sound Power Level (Cooling/Heating): 63/65 dB(A) to 65/67 dB(A)
    • Unit Dimensions (H×W×D): 619×824(+70)×299 mm
    • Product Weight: 39 kg
  • 3 Room Multi (Type 52, 68):
    • Models: CU-3Z52TBE, CU-3Z68TBE
    • Power Source: Single phase, 230 V, 50 Hz
    • Cooling Capacity: 5.20 kW to 6.80 kW
    • Heating Capacity: 6.80 kW to 8.50 kW
    • Sound Pressure Level (Cooling/Heating): 47/48 dB(A) to 51/52 dB(A)
    • Sound Power Level (Cooling/Heating): 61/62 dB(A) to 65/66 dB(A)
    • Unit Dimensions (H×W×D): 795×875(+95)×320 mm
    • Product Weight: 71 kg
  • 4 Room Multi (Type 68, 80):
    • Models: CU-4Z68TBE, CU-4Z80TBE
    • Power Source: Single phase, 230 V, 50 Hz
    • Cooling Capacity: 6.80 kW to 8.00 kW
    • Heating Capacity: 8.50 kW to 9.40 kW
    • Sound Pressure Level (Cooling/Heating): 49/50 dB(A) to 51/52 dB(A)
    • Sound Power Level (Cooling/Heating): 63/64 dB(A) to 67/68 dB(A)
    • Unit Dimensions (H×W×D): 795×875(+95)×320 mm to 999×940×340 mm
    • Product Weight: 72 kg to 80 kg
  • 5 Room Multi (Type 90):
    • Models: CU-5Z90TBE
    • Power Source: Single phase, 230 V, 50 Hz
    • Cooling Capacity: 9.00 kW
    • Heating Capacity: 10.40 kW
    • Sound Pressure Level (Cooling/Heating): 53/54 dB(A)
    • Sound Power Level (Cooling/Heating): 69/70 dB(A)
    • Unit Dimensions (H×W×D): 999×940×340 mm
    • Product Weight: 81 kg

Usage Features

  • Remote Controllers: The system supports various optional remote controllers:
    • Wireless Remote Controller (Model No. CZ-RWS3, Receiver Model No. CZ-RWRY3 for Type Y3, CZ-RWRC3 for all indoor units)
    • Timer Remote Controller (Model No. CZ-RTC4)
    • High-spec Wired Remote Controller (Model No. CZ-RTC5B)
    • Wired Remote Controller (Model No. CZ-RTC6 series)
  • Airflow Direction Adjustment: Refer to the Operating Instructions of the remote controller for adjusting airflow. A specific setting is recommended to protect the ceiling from smudges.
  • Energy Saving Tips:
    • Avoid blocking the air intake and outlet.
    • Use sunshades, blinds, or curtains during cooling operation to prevent direct sunlight.
    • Keep the air filter clean.
    • Keep windows, doors, and other openings closed to prevent conditioned air from escaping.
  • Defrosting Operation: The appliance may initiate defrosting to melt frost on the outdoor unit. During defrosting, the indoor unit fan stops or runs at a very slow speed, and "STANDBY" appears on the display. Heating operation resumes after several minutes, with the fan remaining stopped or slow until the indoor heat exchanger warms up.
  • "DRY" Operation: Once the room temperature reaches the set level, the outdoor unit cycles on and off automatically. The fan speed is set to "breeze" (light wind) when the room temperature is close to the set level.
  • Power Failure Recovery: The unit automatically resumes operation with previous settings after a power failure.

Maintenance Features

  • Safety Precautions: Always turn off and disconnect power before cleaning or servicing. Do not pour water on the indoor unit.
  • Cleaning:
    • Indoor Unit: Wipe with a soft cloth; if very dirty, use a cloth moistened with water. Avoid solvents, harsh chemicals, very hot water, and be careful of sharp metal edges/fins. Use a firm stool or ladder for high-mounted units.
    • Outdoor Unit: The internal coil and other components should be cleaned periodically by a dealer or service center.
  • Air Filter Maintenance: Consult your dealer or service center when the "Filter" indicator appears on the wired remote controller display.
  • Professional Servicing: Internal cleaning of indoor and outdoor units should only be performed by authorized dealers or specialists. In case of malfunction, do not attempt repairs yourself; contact the sales or service dealer.
  • Product Information: For support, have the Model No., Serial No., Date of purchase, Dealer's address, and Phone number ready, as found on the nameplate.
  • Refrigerant Type: Confirm with an authorized dealer or specialist the specified refrigerant type (R32) for usage. Using other refrigerants can cause product damage, burst, and injury.
  • Grounding: Each unit must be properly grounded.
  • Power Mains: Turn the power mains on 5 hours before starting operation for warm-up. Leave the power mains ON for continuous use. Disconnect power when not in use for a long time.