8-5. Test Run Using the Remote Controller
High-spec Wired Remote Controller (CZ-RTC5A)
(1) +EEPPRESSINGTHE
,
and buttons
simultaneously for 4 or more seconds.
4HEh-AINTENANCEFUNCvSCREENAPPEARSONTHE,#$
display.
Maintenance func
1. Outdoor unit error data
2. Service contact
3. RC setting mode
4.Test run
Sel. Page [ ] Confirm
20:30 (THU)
(2) Press the or button to see each menu.
If you wish to see the next screen instantly, press the
or button.
3ELECTh4ESTRUNvONTHE,#$DISPLAYANDPRESSTHE
button.
Maintenance func
1. Outdoor unit error data
2. Service contact
3. RC setting mode
4.Test run
Sel. Page [ ] Confirm
20:30 (THU)
Change the display from OFF to ON by pressing the
or button. Then press the button.
[ ] Confirm
Test run
Change
20:30 (THU)
Test run
ON
START
[]
20:30 (THU)
(1)
(1)
(4)
(3) Press the button. “TEST” will be displayed on the
,#$DISPLAY
TEST
START[]
20:30 (THU)
(4) Press the button. Test run will be started.
4ESTRUNSETTINGMODESCREENAPPEARSONTHE,#$DISPLAY
TEST
20:30 (THU)
COOL
MODE
Timer remote controller (CZ-RTC4)
(1) Press the remote controller
button for 4 seconds or longer.
Then press the
button.
vAPPEARSONTHE,#$DISPLAYWHILETHETESTRUNISINPROGRESS
The temperature cannot be adjusted when in Test Run mode.
(This mode places a heavy load on the machines.
Therefore use it only when performing the test run.)
(2)4HETESTRUNCANBEPERFORMEDUSINGTHE(%!4#//,OR&!.
operation modes.
NOTE
The outdoor units will not operate for approximately 3 minutes after the
power is turned ON and after operation is stopped.
(3) If correct operation is not possible, a code is displayed on the remote
CONTROLLER,#$DISPLAY
(3EETHESECTIONh4ABLEOF3ELF$IAGNOSTIC&UNCTIONSAND
Corrections” and correct the problem.)
(4) After the test run is completed, press the
button again.
Check that “
vDISAPPEARSFROMTHE,#$DISPLAY
(To prevent continuous test runs, this remote controller includes a timer
function that cancels the test run after 60 minutes.)
* If the test run is performed using the wired remote controller, operation
is possible even if the cassette-type ceiling panel has not been
installed. (“P09” display does not occur.)
26
8-6. Precautions
Request that the customer be present when the test run is
performed. At this time, explain the operation manual and
have the customer perform the actual steps.
"ESURETOPASSTHEMANUALSANDWARRANTYCERTIFICATETOTHE
customer.
Check that the 220 – 240 V AC power is not connected to
the inter-unit control wiring connector terminal.
* If 220 – 240 V AC is accidentally applied, the indoor or
OUTDOORUNITCONTROL0#"FUSEWILLBLOWINORDERTOPROTECT
THE0#"#ORRECTTHEWIRINGCONNECTIONS2EMOVETHE
short connector connected to the OC side and reconnect
TOTHE%-'SIDEONTHEOUTDOORCONTROL0#"#UTTHE3!
OUTOFTHEOUTDOORUNITCONTROL0#"4HENDISCONNECTTHE
2P connectors (OC) that are connected to the indoor unit
0#"ANDREPLACETHEMWITH0CONNECTORS%-'
If operation is still not possible after changing the brown
connectors, cut off the jumper (indoor unit) or the varistor
INDOORUNITONTHE0#""ESURETOTURNTHEPOWER/&&
before performing this work.)
/UTDOORUNITCONTROL0#"
CN-EMG
SA1
)NDOORUNITCONTROL0#"
Type U2
Jumper
(JP040)
EMG (CN044, brown)
OC (CN040, blue)
Type T2
Jumper
(JP040)
EMG (CN044, brown)
OC
(CN040, blue)
Jumper
(JP040)
OC
(CN040, blue)
EMG (CN044, brown)
Type F1
OC
(CN040, blue)
Jumper
(JP003)
EMG
(CN044, brown)
Type N1
Type Y2
OC (CN040, blue)
EMG (CN044, brown)
Jumper (JP003)
Type K1
Jumper
(JP003)
EMG
(CN044, brown)
OC
(CN040, blue)