EasyManua.ls Logo

Panasonic S-73MU1E5A - Page 64

Panasonic S-73MU1E5A
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
64
SUPPLEMENT
1. Combination with various type of outdoor units
Unit: mm
1000
D1
E
D2
E
D3
E
D4
e
d1 d2
e
d3
e
d4
18 A
B
C
f
F
1842
953
Capacity
Combination Dimensions of single unit
Distance
between units
Dimensions of
combination unit
Dimensions of single unit
installation hole
Distance
between unit
installation hole
Dimensions of
combination unit
installation hole
1 2 3 4
D1 D2 D3 D4 E(
*
1) E(
*
2) F(
*
1) F(
*
2) d1 d2 d3 d4 e(
*
1) e(
*
2) f(
*
1) f(
*
2)
8HP 8 770 770 770 740 740 740
10HP 10 770 770 770 740 740 740
12HP 12 1180 1180 1180 1150 1150 1150
14HP 14 1180 1180 1180 1150 1150 1150
16HP 16 1180 1180 1180 1150 1150 1150
18HP 18 1540 1540 1540 1510 1510 1510
20HP 20 1540 1540 1540 1510 1510 1510
22HP 10 12 770 1180 60 180 2010 2130 740 1150 90 210 1980 2100
24HP 12 12 1180 1180 60 180 2420 2540 1150 1150 90 210 2390 2510
26HP 10 16 770 1180 60 180 2010 2130 740 1150 90 210 1980 2100
28HP 12 16 1180 1180 60 180 2420 2540 1150 1150 90 210 2390 2510
30HP 14 16 1180 1180 60 180 2420 2540 1150 1150 90 210 2390 2510
32HP 16 16 1180 1180 60 180 2420 2540 1150 1150 90 210 2390 2510
34HP 14 20 1180 1540 60 180 2780 2900 1150 1510 90 210 2750 2870
36HP 16 20 1180 1540 60 180 2780 2900 1150 1510 90 210 2750 2870
38HP 18 20 1540 1540 60 180 3140 3260 1510 1510 90 210 3110 3230
40HP 20 20 1540 1540 60 180 3140
3260 1510 1510 90 210 3110 3230
42HP 10 16 16 770 1180 1180 60 180 3250 3490 740 1150 1150 90 210 3220 3460
44HP 12 16 16 1180 1180 1180 60 180 3660 3900 1150 1150 1150 90 210 3630 3870
46HP 14 16 16 1180 1180 1180 60 180 3660 3900 1150 1150 1150 90 210 3630 3870
48HP 16 16 16 1180 1180 1180 60 180 3660 3900 1150 1150 1150 90 210 3630 3870
50HP 14 16 20 1180 1180 1540 60 180 4020 4260 1150 1150 1510 90 210 3990 4230
52HP 16 16 20 1180 1180 1540 60 180 4020 4260 1150 1150 1510 90 210 3990 4230
54HP 14 20 20 1180 1540 1540 60 180 4380 4620 1150 1510 1510 90 210 4350 4590
56HP 16 20 20 1180 1540 1540 60 180 4380 4620 1150 1510 1510 90 210 4350 4590
58HP 18 20 20 1540 1540 1540 60 180 4740 4980 1510 1510 1510 90 210 4710 4950
60HP 20 20 20 1540 1540 1540 60 180 4740 4980 1510 1510 1510 90 210 4710 4950
62HP 14 16 16 16 1180 1180 1180 1180 60 180 4900 5260 1150 1150 1150 1150 90 210 4870 5230
64HP 16 16 16 16 1180 1180 1180 1180 60 180 4900 5260 1150 1150 1150 1150 90 210 4870 5230
66HP 10 16 20 20 770 1180 1540 1540 60 180 5210 5570 740 1150 1510 1510 90 210 5180 5540
68HP 12 16 20 20 1180 1180 1540 1540 60 180 5620 5980 1150 1150 1510 1510 90 210 5590 5950
70HP 10 20 20 20 770 1540 1540 1540 60 180 5570 5930 740 1510 1510 1510 90 210 5540 5900
72HP 16 16 20 20 1180 1180 1540 1540 60 180 5620 5980 1150 1150 1510 1510 90 210 5590 5950
74HP 16 18 20 20 1180 1540 1540 1540 60 180 5980 6340 1150 1510 1510 1510 90 210 5950 6310
76HP 16 20 20 20 1180 1540 1540 1540 60 180 5980 6340 1150 1510 1510 1510 90 210 5950 6310
78HP 18 20 20 20 1540 1540 1540 1540 60 180 6340 6700
1510 1510 1510 1510 90 210 6310 6670
80HP 20 20 20 20 1540 1540 1540 1540 60 180 6340 6700 1510 1510 1510 1510 90 210 6310 6670
According to the installation site, you may choose the setting position in the depth direction of the anchor bolt from A, B or C.
A: 964: (Installation hole pitch) : For removing tube forward. Use the data with the asterisk (*1) in combination of each unit dimension.
B: 730: (Installation hole pitch) : For removing tube downward. Use the data with the asterisk (*2) in combination of each unit dimension.
C: 730: (Installation hole pitch) : Use the data with the asterisk (*2) in combination of each unit dimension.
Unit
1
Unit
2
Unit
3
Unit
4
00_340994_2WAY_Eng.indb 64 2022/8/4 14:28:56

Other manuals for Panasonic S-73MU1E5A

Related product manuals