EasyManua.ls Logo

Panasonic S-71PN1E5 - User Manual

Panasonic S-71PN1E5
142 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
CV623322089585464609230020
Operating Instructions
Air Conditioner
* Shows U1 type (4-Way Cassette)
ENGLISH
FRANÇAIS
ESPAÑOL
DEUTSCH
ITALIANO
NEDERLANDS
PORTUGUÊS
EΛΛΗΝΙΚΆ
БЪЛГАРСКИ
РУССКИЙ
УКРАЇНСЬКА
2 ~ 13
14 ~ 25
26 ~ 37
38 ~ 49
50 ~ 61
62 ~ 73
74 ~ 85
86 ~ 97
98 ~ 109
110 ~ 121
122 ~ 134
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son intégralité et conservez-le pour toute référence ultérieure.
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese Bedienungsanleitung aufmerksam
durch und bewahren Sie sie für die künftige Verwendung auf.
Prima di utilizzare l’unità, leggere a fondo queste istruzioni per l’uso e conservarle come riferimento futuro.
Преди да започнете експлоатация на този уред, прочетете внимателно тези инструкции и ги
запазете, за да можете да правите справки с тях и в бъдеще.
Lees deze gebruiksinstructies goed door voor u het apparaat gebruikt en bewaar ze voor toekomstig gebruik.
Antes de utilizar o aparelho, leia completamente este manual de instruções e guarde-o para futuras referências.
Перед использованием этого устройства внимательно прочитайте настоящую инструкцию по
эксплуатации и сохраните ее для дальнейших справок.
Уважно прочитайте цю інструкцію з експлуатації перед тим, як увімкнути пристрій, та
збережіть її на майбутнє.
Πριν θέσετε τη μονάδα σε λειτουργία, διαβάστε πολύ καλά αυτές τις οδηγίες χρήσης και
διατηρήστε τις για μελλοντική αναφορά.
Antes de operar la unidad, lea atentamente estas instrucciones de funcionamiento y guárdelas para futuras consultas.
Indoor Units
4-Way
Cassette
60x60 (Y1 type)
S-36PY1E5
S-50PY1E5
Model No.
Indoor Units
4-Way
Cassette
(U1 type)
S-36PU1E5
S-50PU1E5
S-60PU1E5
S-71PU1E5
Indoor Units
Ceiling
(T1 type)
S-36PT1E5
S-50PT1E5
S-60PT1E5
S-71PT1E5
Indoor Units
Wall
Mounted
(K1 type)
S-36PK1E5
S-50PK1E5
S-60PK1E5
S-71PK1E5
Outdoor Units
Single Split
(Single-
phase)
U-50PE1E5
U-60PEY1E5
U-71PEY1E5
Indoor Units
Ducted
(N1 type)
S-36PN1E5
S-50PN1E5
S-60PN1E5
S-71PN1E5
Indoor Units
Low Silhouette
Ducted
(F1 type)
S-36PF1E5
S-50PF1E5
S-60PF1E5
S-71PF1E5
Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan

Table of Contents

Other manuals for Panasonic S-71PN1E5

Questions and Answers

  • E
    Elizabeth DavidsonAug 20, 2025
    Why is my Panasonic Air Conditioner not cooling or heating properly?
    • D
      douglasjohnsonAug 20, 2025
      If your Panasonic Air Conditioner isn't cooling or heating well, check if the air intake or discharge ports of the indoor and outdoor units are blocked by dust or other obstructions. Remove any dust or obstructions you find. Also, check that the wind speed isn't set to 'Low'; change it to 'High' or 'Strong'.
  • H
    Heather MillerAug 22, 2025
    What to do if Panasonic Air Conditioner does not turn on?
    • T
      Terry WilliamsAug 22, 2025
      If your Panasonic Air Conditioner doesn't turn on even when powered, first, press the ON/OFF button on the remote control again. If that doesn't work, check if the breaker is turned off and switch it on. If the fuse is blown, consult your dealer.
  • Q
    quinnblakeAug 25, 2025
    Why does my Panasonic S-71PN1E5 Air Conditioner smell?
    • G
      Gina WalshAug 25, 2025
      Your Panasonic Air Conditioner might smell because indoor odor components like cigarette or cosmetic odors have accumulated and are being discharged. It could also be due to a dusty unit inside. In both cases, it is recommended to consult your dealer.
  • T
    tracyweaverAug 26, 2025
    Why is my Panasonic Air Conditioner emitting fog?
    • V
      Victoria LarsenAug 27, 2025
      If your Panasonic Air Conditioner is emitting fog, it could be due to a dirty heat exchanger inside the unit, requiring cleaning. Also, fog can appear during defrost operation. If the unit inside (heat exchanger) is dirty, consult your dealer as technical engineering is required.
  • B
    brockstephenAug 27, 2025
    Why does the fan on my Panasonic S-71PN1E5 keep running after I turn it off?
    • J
      John MillerAug 27, 2025
      The fan in your Panasonic Air Conditioner may continue to rotate after operation stops to ensure smooth operation or because it's drying the heat exchanger due to specific settings.
  • A
    Andrew YoungAug 29, 2025
    Why won't the wind direction change on my Panasonic S-71PN1E5?
    • K
      Kenneth MoralesAug 30, 2025
      The wind direction on your Panasonic Air Conditioner may not change because when the air discharge temperature is low or during defrost operation, horizontal wind flow is made automatically. Also, the flap position may occasionally be set up individually.
  • S
    Stephanie DavisAug 31, 2025
    Why does the flap operate several times and stops at designated position when I change the wind direction on my Panasonic S-71PN1E5 Air Conditioner?
    • S
      Shawn YoungAug 31, 2025
      When the wind direction is changed, the flap operates after searching for a standard position.
  • J
    Justin PerezSep 2, 2025
    Why is there dewdrop on my Panasonic S-71PN1E5?
    • T
      Tamara PruittSep 2, 2025
      Indoor moisture is cooled by cool wind and accumulated by dewdrop.
  • T
    Taylor WestSep 4, 2025
    Why is my Panasonic S-71PN1E5 discharging dust?
    • J
      Julie ScottSep 4, 2025
      Dust accumulation inside the indoor unit is being discharged.
  • W
    William HopkinsSep 6, 2025
    Why does the fan on my Panasonic Air Conditioner rotate faster than the setting speed at the initial high-speed operation?
    • V
      Vanessa WatsonSep 6, 2025
      This happens for operation check in order to confirm whether the fan motor rotation is within use range.

Summary

Safety Precautions

WARNING Symbol

Symbol indicating hazard for severe personal injury or death.

CAUTION Symbol

Symbol indicating hazard for personal injury or property damage.

Installation Location

Installation WARNING

Avoid installation in areas with fumes, flammable gases, or high heat.

Installation Avoidance Advice

Prevent corrosion by avoiding salty sea air or sulphurous air near the unit.

Electrical Requirements

Electrical Safety CAUTION

Ensure power mains are ON 5 hours prior to system warm-up.

General Safety Instructions

General Operation WARNING

Stop operation and disconnect power immediately if any abnormality occurs.

General Operation CAUTION

For use by trained users; avoid operating via mains switch.

Refrigerant Information

General Information

Operation Condition Ranges

Specifies indoor and outdoor temperature ranges for cooling and heating.

Equipment Disposal Guidance

Instructions for proper disposal of old electrical equipment and batteries.

Unit Operation

Indoor Unit Component Identification

Identifies key components of various indoor unit types.

Adjusting Airflow Direction

Setting Airflow Direction

How to change airflow direction using the FLAP button.

Activating Swing Operation

Steps to activate the automatic swing operation for airflow.

Stopping Swing Operation

How to stop the flap swing operation at a desired position.

Multi-Unit Airflow Control

Special Operating Remarks

DRY Operation Mode

Details the function and limitations of the DRY operation mode.

Heating Performance Considerations

Discusses factors affecting heating efficiency, especially in cold weather.

Defrosting Cycle Explanation

Describes the defrosting process and associated indicators.

Care and Cleaning Guidelines

Instructions and warnings for cleaning the indoor and outdoor units.

Troubleshooting Guide

Indoor Unit Troubleshooting

Lists symptoms and causes for common indoor unit issues.

Outdoor Unit Troubleshooting

Lists symptoms and causes for common outdoor unit issues.

Pre-Service Checklist

Energy Saving Tips

Product Specifications

4-Way Cassette (U1 Type) Specifications

Technical specifications for the 4-Way Cassette (U1 type) units.

4-Way Cassette 60 x60 (Y1 Type) Specifications

Technical specifications for the 4-Way Cassette 60x60 (Y1 type) units.

Low Silhouette Ducted (F1 Type) Specifications

Technical specifications for the Low Silhouette Ducted (F1 type) units.

Ceiling (T1 Type) Specifications

Technical specifications for the Ceiling (T1 type) units.

Wall Mounted (K1 Type) Specifications

Technical specifications for the Wall Mounted (K1 type) units.

Ducted (N1 Type) Specifications

Technical specifications for the Ducted (N1 type) units.

Single Split Outdoor Unit Specifications

Technical specifications for the Single Split Outdoor Units.

Panasonic S-71PN1E5 Specifications

General IconGeneral
Cooling Capacity7.1 kW
Heating Capacity8.0 kW
RefrigerantR32
Coefficient of Performance (COP)4.0
Power Supply220-240 V, 50 Hz
TypeSplit System Air Conditioner

Related product manuals