Mi
SAFETY
PRECAUTION
mh
wWhHND
prevent
the
customer
from
being
exposed
to
a
shock
hazard.
e
INSULATION
RESISTANCE
TEST
(This
‘safety
precaution”
is
applied
in
U.S.A.)
.
Before
servicing,
unplug
the
power
cord
to
prevent
an
electric
shock.
.
When
replacing
parts,
use
only
manufacturer’s
recommended
components
for
safety.
.
Check
the
condition
of
the
power
cord.
Replace
if
wear
or
damage
Is
evident.
.
After
servicing,
be
sure
to
restore
the
lead
dress,
insulation
barriers,
insulation
papers,
shields,
etc.
.
Before
returning
the
serviced
equipment
to
the
customer,
be
sure
to
make
the
following
insulation resistance
test
to
1.
Unplug
the
power
cord
and
short
the
two
prongs
of
the
plug
with
a
jumper
wire.
2.
Turn
on
the
power
switch.
3.
Measure
the
resistance
value
with
ohmmeter
between
the
jumpered
AC
plug
and
each
exposed
metal
cabinet
part,
such
as
screwheads
antenna,
control
shafts,
handle
brackets,
etc.
Equipment
with
antenna
terminals
should
read
between
3MQ
and
5.2M2Q
to
all
exposed
parts.
all
exposed
parts.
(Fig.
B)
Note:
Antenna
terminal
Exposed
2
Exposed
metal
Ch
metal
part
part
|
Ohmmeter
(Fig.
A)
Resistance
=
3M2—5.2MQ
(Fig.
A)
Equipment
without
antenna
terminals
should
read
approximately
infinity
to
Some
exposed
parts
may
be
isolated
from
the
chassis
by
design.
These
will
read
infinity.
(Fig.
B)
Resistance
=
Approx
oo
4.
|f
the
measurement
is
outside
the
specified
limits,
there
is
a
possibility
of
a
shock
hazard.
The
equipment
should
be
repaired
and
rechecked
before
It
is
returned
to
the
customer.
Mi
PROTECTION
CIRCUITRY
The
protection
circuitry
may
have
operated
if
either
of
the
following
conditions
is
noticed:
@
No
sound
is
neard
when
the
power
is
turned
on.
@
Sound
stops
during
a
performance.
The
function
of
this
circuitry
is
to
prevent
circuitry
damage
if,
for
example,
the
positive
and
negative
speaker
connection
wires
are
‘‘shorted’’,
or
if
speaker
systems
with
an
impedance
less
than
the
indicated
rated
impedance
of
this
unit
are
used.
Mi
BEFORE
REPAIR
If
this
occurs,
follow
the
procedure
outlines
below:
1.
Turn
off
the
power.
2.
Determine
the
cause
of
the
problem
and
correct
It.
3.
Turn
on
the
power
once
again
after
one
minute.
Note
When
the
protection
circuitry
functions,
the
unit
will
not
operate
unless
the
power
is
first
turned
off
and
then
on
again.
Disconnect
AC
power,
Discharge
both
Power
Supply
Capacitors
C703
and
C704
through
a
102,
5W
resistor
to
ground.
DO
NOT
SHORT-CIRCUIT
DIRECTLY
(witha
screwdriver
blade,
for
instance),
as
this
may
distroy
solid
state
devices.
After
repairs
are
completed,
restore
power
gradually
using
a
variac,
to
avoid
overcurrent.
Current
consumption
at
120V,
60Hz
in
NO
SIGNAL
mode
should
be
250
~
500mA.
e
Accessories
@AC
power
supplycord
............
1
e
Flat
cable
for
remote-control
(SJA172—1)
operation
....
1
(SWKUV96KM)
eBatteries..........
2
(UM—3NEP)
@
Remote-control