Operating Instructions
Air Conditioner
ENGLISH
Before operating the unit, read these operating instructions thoroughly and
keep them for future reference.
Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan
WEB-ACXF55-28600-EN
4-Way Cassette 60 × 60
(Type Y3)
Model No.
INDOOR UNIT
4-Way Cassette 60 × 60
(Type Y3)
S-M20PY3E
S-25PY3E
S-36PY3E
S-50PY3E
S-60PY3E
OUTDOOR UNIT
Single Split
See page 12.
RAC Multi
See page 19 (Supplement).
OI_00_331027_EN.indb 1 2021/9/1 13:03:17

Questions and Answers

  • O
    Olivia CooleyAug 18, 2025
    Why is my Panasonic Air Conditioner discharging dust?
    • Y
      youngpatrickAug 18, 2025
      Dust discharge may occur if dust has accumulated inside the indoor unit. Ensure that nanoe™ X is set to ON. If nanoe™ X is already ON, it may be considered abnormal, and you should contact your dealer.
  • S
    Susan DouglasAug 21, 2025
    What to do if my Panasonic U-100PZ3E5 Air Conditioner smells bad?
    • M
      Madison WellsAug 21, 2025
      The unit inside is dirty and has accumulated odor components. Contact your dealer for assistance.
  • J
    John CollinsAug 23, 2025
    Why is my Panasonic U-100PZ3E5 Air Conditioner making noise during heating?
    • C
      Christopher DoughertyAug 23, 2025
      The noise you are hearing during heating operation is likely due to the defrost operation being in process.
  • M
    markcalderonAug 26, 2025
    Why does my Panasonic Air Conditioner smell when it's on?
    • C
      christopher37Aug 26, 2025
      The discharged air may smell because indoor odor components, cigarette odor, and cosmetic odors have accumulated in the air conditioner, and are being discharged.
  • S
    Stephanie OlsonAug 28, 2025
    Why is my Panasonic U-100PZ3E5 making noise?
    • N
      navarroangelaAug 28, 2025
      The noise you hear could be due to refrigerant liquid flowing inside the unit, drainage water moving through the drain pipe, or temperature changes affecting the unit's parts.
  • A
    ahernandezAug 30, 2025
    Why does the fan keep running after I turn off my Panasonic U-100PZ3E5 Air Conditioner?
    • T
      tristanjamesAug 30, 2025
      The fan may continue to rotate after the unit is turned off to dry the heat exchanger, depending on the settings. This is also done to ensure smoother operation.
  • T
    Timothy LeeSep 2, 2025
    Why does my Panasonic U-100PZ3E5 change the airflow direction by itself?
    • S
      Seth DunnSep 2, 2025
      The airflow direction may change automatically during heating operation if the air discharge temperature is low, or during defrost operation, resulting in a horizontal wind flow.
  • P
    Paige GreerSep 5, 2025
    Why is dust coming out of my Panasonic U-100PZ3E5 Air Conditioner?
    • B
      Bobby HoffmanSep 5, 2025
      Dust may be discharged because it has accumulated inside the indoor unit.
  • J
    Jennifer StephensonSep 7, 2025
    What does it mean when my Panasonic Air Conditioner makes a humming noise?
    • A
      Abigail HoodSep 7, 2025
      The humming noise you hear is the sound of nanoe™ X being discharged.
  • M
    Martin DeckerSep 9, 2025
    Why is my Panasonic U-100PZ3E5 making noise during heating operation?
    • T
      Tamara RhodesSep 10, 2025
      The noise you're hearing during heating operation is likely due to the defrost operation being in process.

Summary

Safety Precautions and Product Information

General Safety Warnings

Explains symbols for hazards and unsafe practices related to appliance use and user safety.

Electrical and Installation Safety

Refrigerant Handling and Electrical Safety

Details refrigerant hazards, electrical installation requirements, and grounding for safe operation.

Safe Servicing and Handling

Advises against self-repair, unqualified cleaning, and emphasizes professional service for safety.

Operational Safety and Precautions

Abnormality and Failure Handling

Lists symptoms of malfunction and instructs users to stop operation and contact a dealer.

Installation, Usage, and Disposal

Installation and Wiring Guidelines

Specifies requirements for qualified installation, voltage checks, wiring, and grounding.

Maintenance and Operation Mechanism

Maintenance Procedures

Details cleaning instructions for indoor and outdoor units, including air filter maintenance.

nanoe X Functionality

nanoe X Display and Benefits

Shows how nanoe™™ X appears on remote controllers and describes its air purification benefits.

Internal Cleaning Function

Troubleshooting Guide

Indoor Unit Troubleshooting

Lists common indoor unit symptoms like noise, odors, fogging, and airflow problems with causes.

Outdoor Unit and nanoe X Troubleshooting

Addresses outdoor unit symptoms and troubleshooting for nanoe™™ X display issues.

Service Request Preparation

Troubleshooting Unit Operation

Provides steps for no operation or poor performance, checking basic causes before service.

Contacting Dealer for Service

Instructs users to stop operation and contact the dealer with serial numbers and error codes if problems persist.

Indoor Unit Specifications

Outdoor Unit Specifications (Single Split - Europe)

Outdoor Unit Specifications (Single Split - Oceania)

Supplement: Multi Split Indoor Unit Specifications

Supplement: Multi Split Outdoor Unit Specifications

Overview

This document provides operating instructions for the Panasonic 4-Way Cassette 60 x 60 (Type Y3) air conditioner, including both indoor and outdoor units, as well as multi-split systems.

Function Description

The Panasonic 4-Way Cassette 60 x 60 (Type Y3) is a commercial air conditioner indoor unit designed to provide comfortable room conditions. It incorporates a biocidal product that generates ionized air to deactivate bacteria and viruses in the air and on surfaces, and inhibits mold growth. The active substances are free radicals generated in situ from ambient air or water. The unit is designed for use in shops, light industry, farms, or commercial settings by expert or trained users.

The air conditioner features a nanoe™ X Function for a fresher and cleaner environment. This function generates negative ions to improve air quality, reduce odors, and constrain the propagation of mold and bacteria. The nanoe™ X function operates automatically upon purchase, but can be set to OFF via the remote controller.

An Internal Cleaning Function is activated when cooling or dry operation stops. This function performs internal drying and nanoe™ X circulation airflow to suppress mold proliferation inside the unit (airflow passage, fan, heat exchanger). The duration of this operation is up to 75 minutes. The effectiveness of mold proliferation inhibition may vary depending on the installation environment or operating hours.

Important Technical Specifications

Indoor Unit (4-Way Cassette 60 x 60, Type Y3)

  • Model Numbers: S-M20PY3E, S-25PY3E, S-36PY3E, S-50PY3E, S-60PY3E
  • Power Source (Europe): 220-230-240 V~ 50 Hz
  • Power Source (Oceania): 230-240 V~ 50 Hz
  • Cooling Capacity:
    • S-25PY3E: 2.5 kW (8,500 BTU/h)
    • S-36PY3E: 3.6 kW (12,300 BTU/h)
    • S-50PY3E: 5.0 kW (17,100 BTU/h)
    • S-60PY3E: 6.0 kW (20,500 BTU/h)
  • Heating Capacity:
    • S-25PY3E: 3.2 kW (10,900 BTU/h)
    • S-36PY3E: 3.6 kW (12,300 BTU/h)
    • S-50PY3E: 5.0 kW (17,100 BTU/h)
    • S-60PY3E: 6.0 kW (20,500 BTU/h)
  • Cooling Electric Power Input (nanoe™ X OFF):
    • S-25PY3E: -
    • S-36PY3E: 0.021 kW
    • S-50PY3E: 0.034 kW
    • S-60PY3E: 0.048 kW
  • Heating Electric Power Input (nanoe™ X OFF):
    • S-25PY3E: -
    • S-36PY3E: 0.019 kW
    • S-50PY3E: 0.032 kW
    • S-60PY3E: 0.046 kW
  • Sound Pressure Level (Cooling/Heating):
    • S-25PY3E: High 31/33 dB(A), Medium 28/28 dB(A), Low 25/25 dB(A)
    • S-36PY3E: High 34/34 dB(A), Medium 30/30 dB(A), Low 25/25 dB(A)
    • S-50PY3E: High 39/39 dB(A), Medium 34/34 dB(A), Low 27/27 dB(A)
    • S-60PY3E: High 43/43 dB(A), Medium 37/37 dB(A), Low 31/31 dB(A)
  • Sound Power Level (Cooling/Heating):
    • S-25PY3E: High 46/46 dB(A), Medium 43/43 dB(A), Low 40/40 dB(A)
    • S-36PY3E: High 49/49 dB(A), Medium 45/45 dB(A), Low 40/40 dB(A)
    • S-50PY3E: High 54/54 dB(A), Medium 49/49 dB(A), Low 42/42 dB(A)
    • S-60PY3E: High 58/58 dB(A), Medium 52/52 dB(A), Low 46/46 dB(A)
  • Unit Dimensions (H×W×D): 273×625×625 mm
  • Net Weight: 17.8 kg
  • Operation Condition Temperature Range:
    • Cooling mode: 18°C~32°C DB
    • Heating mode: 16°C~30°C DB

Outdoor Unit (Single Split, R32 Refrigerant)

  • PZH2 Series (Europe):
    • Models: U-36PZH2E5, U-50PZH2E5, U-71PZH2E5/E8, U-100PZH2E5/E8, U-125PZH2E5/E8, U-140PZH2E5/E8
    • Power Source: 220-230-240 V~ 50 Hz (1-phase), 380-400-415 V 3N~ 50 Hz (3-phase)
    • Cooling Capacity: 3.6 kW to 14.0 kW
    • Heating Capacity: 4.0 kW to 16.0 kW
    • Sound Pressure Level (Cooling/Heating): 43/44 dB(A) to 54/54 dB(A)
    • Sound Power Level (Cooling/Heating): 62/64 dB(A) to 71/71 dB(A)
    • Unit Dimensions (H×W×D): 695×875×320 mm to 1,416×940×340 mm
    • Net Weight: 43 kg to 99 kg
    • Operation Condition Temperature Range: Cooling -15°C~46°C DB (some models -20°C), Heating -20°C~24°C DB
  • PZ2 Series (Europe):
    • Models: U-100PZ2E5/E8
    • Power Source: 220-230-240 V~ 50 Hz (1-phase), 380-400-415 V 3N~ 50 Hz (3-phase)
    • Cooling Capacity: 10.0 kW
    • Heating Capacity: 10.0 kW
    • Sound Pressure Level (Cooling/Heating): 52/52 dB(A)
    • Sound Power Level (Cooling/Heating): 70/70 dB(A)
    • Unit Dimensions (H×W×D): 996×980×370 mm
    • Net Weight: 90 kg
    • Operation Condition Temperature Range: Cooling -10°C~43°C DB, Heating -15°C~24°C DB
  • PZH3 Series (Europe):
    • Models: U-36PZH3E5, U-50PZH3E5, U-60PZH3E5, U-71PZH3E5/E8, U-100PZH3E5/E8, U-125PZH3E5/E8, U-140PZH3E5/E8
    • Power Source: 220-230-240 V~ 50 Hz (1-phase), 380-400-415 V 3N~ 50 Hz (3-phase)
    • Cooling Capacity: 3.6 kW to 14.0 kW
    • Heating Capacity: 4.0 kW to 16.0 kW
    • Sound Pressure Level (Cooling/Heating): 43/44 dB(A) to 54/54 dB(A)
    • Sound Power Level (Cooling/Heating): 62/64 dB(A) to 71/71 dB(A)
    • Unit Dimensions (H×W×D): 695×875×320 mm to 1,416×940×340 mm
    • Net Weight: 42 kg to 98 kg
    • Operation Condition Temperature Range: Cooling -15°C~48°C DB, Heating -20°C~24°C DB
  • PZ3 Series (Europe):
    • Models: U-25PZ3E5, U-36PZ3E5, U-50PZ3E5, U-60PZ3E5A, U-100PZ3E5/E8, U-125PZ3E5/E8
    • Power Source: 220-230-240 V~ 50 Hz (1-phase), 380-400-415 V 3N~ 50 Hz (3-phase)
    • Cooling Capacity: 2.5 kW to 12.5 kW
    • Heating Capacity: 3.2 kW to 12.5 kW
    • Sound Pressure Level (Cooling/Heating): 46/47 dB(A) to 55/55 dB(A)
    • Sound Power Level (Cooling/Heating): 64/66 dB(A) to 73/73 dB(A)
    • Unit Dimensions (H×W×D): 619×824×299 mm to 996×980×370 mm
    • Net Weight: 32 kg to 87 kg
    • Operation Condition Temperature Range: Cooling -10°C~43°C DB, Heating -15°C~24°C DB
  • PZ3 Series (Oceania):
    • Models: U-25PZ3R5, U-36PZ3R5, U-50PZ3R5, U-60PZ3R5
    • Power Source: 230-240 V~ 50 Hz
    • Cooling Capacity: 2.5 kW to 6.0 kW
    • Heating Capacity: 3.2 kW to 6.0 kW
    • Sound Pressure Level (Cooling/Heating): 48/49 dB(A)
    • Sound Power Level (Cooling/Heating): 66/67 dB(A)
    • Unit Dimensions (H×W×D): 619×824×299 mm to 695×875×320 mm
    • Net Weight: 31 kg to 43 kg
    • Operation Condition Temperature Range: Cooling -10°C~43°C DB, Heating -15°C~24°C DB

RAC Multi Outdoor Unit (R32 Refrigerant)

  • 2 Room Multi (Type 35, 41, 50):
    • Models: CU-2Z35TBE, CU-2Z41TBE, CU-2Z50TBE
    • Power Source: Single phase, 230 V, 50 Hz
    • Cooling Capacity: 3.50 kW to 5.00 kW
    • Heating Capacity: 4.20 kW to 5.60 kW
    • Sound Pressure Level (Cooling/Heating): 48/50 dB(A) to 50/52 dB(A)
    • Sound Power Level (Cooling/Heating): 63/65 dB(A) to 65/67 dB(A)
    • Unit Dimensions (H×W×D): 619×824(+70)×299 mm
    • Product Weight: 39 kg
  • 3 Room Multi (Type 52, 68):
    • Models: CU-3Z52TBE, CU-3Z68TBE
    • Power Source: Single phase, 230 V, 50 Hz
    • Cooling Capacity: 5.20 kW to 6.80 kW
    • Heating Capacity: 6.80 kW to 8.50 kW
    • Sound Pressure Level (Cooling/Heating): 47/48 dB(A) to 51/52 dB(A)
    • Sound Power Level (Cooling/Heating): 61/62 dB(A) to 65/66 dB(A)
    • Unit Dimensions (H×W×D): 795×875(+95)×320 mm
    • Product Weight: 71 kg
  • 4 Room Multi (Type 68, 80):
    • Models: CU-4Z68TBE, CU-4Z80TBE
    • Power Source: Single phase, 230 V, 50 Hz
    • Cooling Capacity: 6.80 kW to 8.00 kW
    • Heating Capacity: 8.50 kW to 9.40 kW
    • Sound Pressure Level (Cooling/Heating): 49/50 dB(A) to 51/52 dB(A)
    • Sound Power Level (Cooling/Heating): 63/64 dB(A) to 67/68 dB(A)
    • Unit Dimensions (H×W×D): 795×875(+95)×320 mm to 999×940×340 mm
    • Product Weight: 72 kg to 80 kg
  • 5 Room Multi (Type 90):
    • Models: CU-5Z90TBE
    • Power Source: Single phase, 230 V, 50 Hz
    • Cooling Capacity: 9.00 kW
    • Heating Capacity: 10.40 kW
    • Sound Pressure Level (Cooling/Heating): 53/54 dB(A)
    • Sound Power Level (Cooling/Heating): 69/70 dB(A)
    • Unit Dimensions (H×W×D): 999×940×340 mm
    • Product Weight: 81 kg

Usage Features

  • Remote Controllers: The system supports various optional remote controllers:
    • Wireless Remote Controller (Model No. CZ-RWS3, Receiver Model No. CZ-RWRY3 for Type Y3, CZ-RWRC3 for all indoor units)
    • Timer Remote Controller (Model No. CZ-RTC4)
    • High-spec Wired Remote Controller (Model No. CZ-RTC5B)
    • Wired Remote Controller (Model No. CZ-RTC6 series)
  • Airflow Direction Adjustment: Refer to the Operating Instructions of the remote controller for adjusting airflow. A specific setting is recommended to protect the ceiling from smudges.
  • Energy Saving Tips:
    • Avoid blocking the air intake and outlet.
    • Use sunshades, blinds, or curtains during cooling operation to prevent direct sunlight.
    • Keep the air filter clean.
    • Keep windows, doors, and other openings closed to prevent conditioned air from escaping.
  • Defrosting Operation: The appliance may initiate defrosting to melt frost on the outdoor unit. During defrosting, the indoor unit fan stops or runs at a very slow speed, and "STANDBY" appears on the display. Heating operation resumes after several minutes, with the fan remaining stopped or slow until the indoor heat exchanger warms up.
  • "DRY" Operation: Once the room temperature reaches the set level, the outdoor unit cycles on and off automatically. The fan speed is set to "breeze" (light wind) when the room temperature is close to the set level.
  • Power Failure Recovery: The unit automatically resumes operation with previous settings after a power failure.

Maintenance Features

  • Safety Precautions: Always turn off and disconnect power before cleaning or servicing. Do not pour water on the indoor unit.
  • Cleaning:
    • Indoor Unit: Wipe with a soft cloth; if very dirty, use a cloth moistened with water. Avoid solvents, harsh chemicals, very hot water, and be careful of sharp metal edges/fins. Use a firm stool or ladder for high-mounted units.
    • Outdoor Unit: The internal coil and other components should be cleaned periodically by a dealer or service center.
  • Air Filter Maintenance: Consult your dealer or service center when the "Filter" indicator appears on the wired remote controller display.
  • Professional Servicing: Internal cleaning of indoor and outdoor units should only be performed by authorized dealers or specialists. In case of malfunction, do not attempt repairs yourself; contact the sales or service dealer.
  • Product Information: For support, have the Model No., Serial No., Date of purchase, Dealer's address, and Phone number ready, as found on the nameplate.
  • Refrigerant Type: Confirm with an authorized dealer or specialist the specified refrigerant type (R32) for usage. Using other refrigerants can cause product damage, burst, and injury.
  • Grounding: Each unit must be properly grounded.
  • Power Mains: Turn the power mains on 5 hours before starting operation for warm-up. Leave the power mains ON for continuous use. Disconnect power when not in use for a long time.

Panasonic U-100PZ3E5 Specifications

General IconGeneral
BrandPanasonic
ModelU-100PZ3E5
CategoryAir Conditioner
LanguageEnglish

Related product manuals