EasyManua.ls Logo

Panasonic U-4LE2R5 - User Manual

Panasonic U-4LE2R5
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Model No.
Outdoor Units
HP = horsepower
Type Outdoor Unit Type
Rated Capacity
4 HP 5 HP 6 HP
LE2 mini VRF System
U-4LE2R5 U-5LE2R5 U-6LE2R5
U-4LE2R5E* U-5LE2R5E* U-6LE2R5E*
*
High-Durable model
• To be connecting Indoor Unit
Indoor Units
Type Indoor Unit Type
Rated Capacity
22 28 36 45 56 60
D1 1-Way Cassette
S-28MD1E5 S-36MD1E5 S-45MD1E5 S-56MD1E5
L1 2-Way Cassette
S-22ML1E5 S-28ML1E5 S-36ML1E5 S-45ML1E5 S-56ML1E5
U2 4-Way Cassette
S-22MU2E5A S-28MU2E5A S-36MU2E5A S-45MU2E5A S-56MU2E5A S-60MU2E5A
Y2 4-Way Cassette 60 × 60
S-22MY2E5A S-28MY2E5A S-36MY2E5A S-45MY2E5A S-56MY2E5A
K1 Wall-Mounted
S-45MK1E5A S-56MK1E5A
K2 Wall-Mounted
S-22MK2E5A S-28MK2E5A S-36MK2E5A S-45MK2E5A S-56MK2E5A
T2 Ceiling
S-36MT2E5A S-45MT2E5A S-56MT2E5A
F2 Low Silhouette Ducted
S-22MF2E5A S-28MF2E5A S-36MF2E5A S-45MF2E5A S-56MF2E5A S-60MF2E5A
M1 Slim Low Static Ducted
S-22MM1E5A S-28MM1E5A S-36MM1E5A S-45MM1E5A S-56MM1E5A
P1 Floor Standing
S-22MP1E5 S-28MP1E5 S-36MP1E5 S-45MP1E5 S-56MP1E5
R1 Concealed Floor Standing
S-22MR1E5 S-28MR1E5 S-36MR1E5 S-45MR1E5 S-56MR1E5
Z1 Slim Type Ducted
S-22MZ1H4A S-28MZ1H4A S-36MZ1H4A S-45MZ1H4A S-56MZ1H4A S-60MZ1H4A
Type Indoor Unit Type
Rated Capacity
71 / 73 90 106 / 112 140 160
D1 1-Way Cassette
S-73MD1E5
L1 2-Way Cassette
S-73ML1E5
U2 4-Way Cassette
S-73MU2E5A S-90MU2E5A S-106MU2E5A S-140MU2E5A S-160MU2E5A
K1 Wall-Mounted
S-73MK1E5A S-106MK1E5A
K2 Wall-Mounted
S-73MK2E5A S-106MK2E5A
T2 Ceiling
S-73MT2E5A S-106MT2E5A S-140MT2E5A
F2 Low Silhouette Ducted
S-73MF2E5A S-90MF2E5A S-106MF2E5A S-140MF2E5A S-160MF2E5A
E1
High Static Pressure Ducted
S-73ME1E5 S-106ME1E5 S-140ME1E5
Ducted
S-90ME1R5 S-112ME1R5 S-140ME1R5 S-160ME1R5
P1 Floor Standing
S-71MP1E5
R1 Concealed Floor Standing
S-71MR1E5
Z1 Slim Type Ducted
S-73MZ1H4A
Read through the Installation Instructions before you proceed with the installation. In particular, you will need to read under
the “ IMPORTANT ! ” section at the top of the page.
Air Conditioner
This air conditioner uses the refrigerant R410A.
INSTALLATION INSTRUCTIONS
ACXF60-16410
00_291827_2WAY_Eng.indb 1 2017/7/5 13:41:23

Questions and Answers

  • H
    htaylorAug 5, 2025
    Why is my Panasonic U-4LE2R5 cooling or heating poorly?
    • A
      Ann ClarkAug 5, 2025
      If your Panasonic Air Conditioner's cooling or heating performance is poor, check if the air inlet or outlet of the indoor and outdoor units are blocked by dust and remove any dust. Also, ensure the air speed control is set to 'High' or 'Strong'. Verify that the temperature settings are correct by lowering the temperature setting or setting it to 'High' or 'Strong'. Finally, consider that direct sunlight exposure in cooling mode can affect performance.

Panasonic U-4LE2R5 Specifications

General IconGeneral
BrandPanasonic
ModelU-4LE2R5
CategoryAir Conditioner
LanguageEnglish

Related product manuals