EasyManua.ls Logo

Panasonic U-50PE1E5 User Manual

Panasonic U-50PE1E5
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
CV623322089585464609230020
Operating Instructions
Air Conditioner
* Shows U1 type (4-Way Cassette)
ENGLISH
FRANÇAIS
ESPAÑOL
DEUTSCH
ITALIANO
NEDERLANDS
PORTUGUÊS
EΛΛΗΝΙΚΆ
БЪЛГАРСКИ
РУССКИЙ
УКРАЇНСЬКА
2 ~ 13
14 ~ 25
26 ~ 37
38 ~ 49
50 ~ 61
62 ~ 73
74 ~ 85
86 ~ 97
98 ~ 109
110 ~ 121
122 ~ 134
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son intégralité et conservez-le pour toute référence ultérieure.
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese Bedienungsanleitung aufmerksam
durch und bewahren Sie sie für die künftige Verwendung auf.
Prima di utilizzare l’unità, leggere a fondo queste istruzioni per l’uso e conservarle come riferimento futuro.
Преди да започнете експлоатация на този уред, прочетете внимателно тези инструкции и ги
запазете, за да можете да правите справки с тях и в бъдеще.
Lees deze gebruiksinstructies goed door voor u het apparaat gebruikt en bewaar ze voor toekomstig gebruik.
Antes de utilizar o aparelho, leia completamente este manual de instruções e guarde-o para futuras referências.
Перед использованием этого устройства внимательно прочитайте настоящую инструкцию по
эксплуатации и сохраните ее для дальнейших справок.
Уважно прочитайте цю інструкцію з експлуатації перед тим, як увімкнути пристрій, та
збережіть її на майбутнє.
Πριν θέσετε τη μονάδα σε λειτουργία, διαβάστε πολύ καλά αυτές τις οδηγίες χρήσης και
διατηρήστε τις για μελλοντική αναφορά.
Antes de operar la unidad, lea atentamente estas instrucciones de funcionamiento y guárdelas para futuras consultas.
Indoor Units
4-Way
Cassette
60x60 (Y1 type)
S-36PY1E5
S-50PY1E5
Model No.
Indoor Units
4-Way
Cassette
(U1 type)
S-36PU1E5
S-50PU1E5
S-60PU1E5
S-71PU1E5
Indoor Units
Ceiling
(T1 type)
S-36PT1E5
S-50PT1E5
S-60PT1E5
S-71PT1E5
Indoor Units
Wall
Mounted
(K1 type)
S-36PK1E5
S-50PK1E5
S-60PK1E5
S-71PK1E5
Outdoor Units
Single Split
(Single-
phase)
U-50PE1E5
U-60PEY1E5
U-71PEY1E5
Indoor Units
Ducted
(N1 type)
S-36PN1E5
S-50PN1E5
S-60PN1E5
S-71PN1E5
Indoor Units
Low Silhouette
Ducted
(F1 type)
S-36PF1E5
S-50PF1E5
S-60PF1E5
S-71PF1E5
Panasonic Corporation
1006 Kadoma, Kadoma City, Osaka, Japan

Table of Contents

Other manuals for Panasonic U-50PE1E5

Questions and Answers:

Panasonic U-50PE1E5 Specifications

General IconGeneral
BrandPanasonic
ModelU-50PE1E5
CategoryAir Conditioner
LanguageEnglish

Summary

PRODUCT INFORMATION

SAFETY PRECAUTIONS

Warning Symbol Description

Describes a hazard leading to severe personal injury or death.

Caution Symbol Description

Describes a hazard leading to personal injury or property damage.

INSTALLATION AND ELECTRICAL REQUIREMENTS

Installation Location Guidelines

Covers recommended installation practices, warnings, and avoidance areas.

Electrical Requirements and Safety

Details wiring codes, grounding, and power mains operation notes.

SAFETY INSTRUCTIONS

General Safety Precautions

Covers handling, environment, power, physical safety, cleaning, and repair procedures.

Handling Abnormalities and Failures

Steps to stop use and handle malfunctions, including specific examples.

User Cautions and Considerations

Specific user actions, maintenance, children, and room comfort precautions.

IMPORTANT INFORMATION REGARDING THE REFRIGERANT USED

INFORMATION

Operation Condition

Specifies the indoor and outdoor temperature ranges for cooling and heating modes.

Disposal of Old Equipment and Batteries

Provides guidance on proper disposal of electrical items and used batteries.

OPERATION

Names of Parts - Indoor Unit

Identifies key components of various indoor unit types like Cassette, Ducted, Wall Mounted.

Remote Controllers

Information on optional wireless and wired remote controllers for operation.

ADJUSTING AIRFLOW DIRECTION

Setting Airflow Direction

How to set the vertical flap direction and activate swing operation using the FLAP button.

Airflow Direction Settings

Details on flap positions for heating, cooling, and fan operations.

Stopping Swing Operation

Procedure to stop the flap swing at a desired position.

ADJUSTING AIRFLOW DIRECTION (CONTINUED)

Airflow Control for Specific Units

Details airflow adjustments for 4-way cassette, ceiling, wall-mounted, and ducted units.

ADJUSTING AIRFLOW DIRECTION FOR MULTIPLE INDOOR UNITS USING SINGLE REMOTE CONTROLLER (WIRED)

Unit Selection for Airflow Control

How to select individual indoor units for airflow adjustment using the UNIT button.

Airflow Direction Settings for Multiple Units

Illustrates unit numbering and selection for controlling airflow across multiple units.

SPECIAL REMARKS AND CARE

Operation Modes and Cleaning

Covers DRY mode, heating, defrosting, power failure, and general cleaning advice.

Safety and Maintenance

Highlights safety during cleaning, indoor/outdoor unit maintenance.

TROUBLESHOOTING

Indoor Unit Symptoms and Causes

Lists common indoor unit issues (noise, odor, fog, dust) and their probable causes.

Outdoor Unit Symptoms and Causes

Lists common outdoor unit issues (no operation, noise, steam) and their probable causes.

CHECK BEFORE REQUIRING SERVICES

Pre-Service Checks and Service Contact

Covers troubleshooting steps before service and how to contact support.

TIPS FOR ENERGY SAVING

Energy Saving Practices and Avoidance

Provides tips on efficient operation, filter maintenance, and avoiding heat gain.

SPECIFICATIONS - 4-Way Cassette (U1) and 60x60 (Y1) Types

4-Way Cassette (U1 type) Specifications

Details model names, power source, cooling/heating capacity, sound levels, and dimensions.

4-Way Cassette 60x60 (Y1 type) Specifications

Lists model names, power, capacity, sound levels, and dimensions for Y1 type.

SPECIFICATIONS - Low Silhouette Ducted (F1) and Ceiling (T1) Types

Low Silhouette Ducted (F1 type) Specifications

Provides specifications for F1 type ducted units including capacity, sound, and dimensions.

Ceiling (T1 type) Specifications

Details specifications for T1 ceiling units: model, power, capacity, sound, and dimensions.

SPECIFICATIONS - Wall Mounted (K1), Ducted (N1), and Single Split Outdoor Unit Types

Wall Mounted (K1 type) Specifications

Includes model names, power, capacity, sound pressure/power levels, and dimensions.

Ducted (N1 type) Specifications

Lists specifications for N1 ducted units: model, power, capacity, sound, and dimensions.

Single Split Outdoor Unit Specifications

Details specifications for outdoor units: model, power, capacity, sound, and dimensions.

Related product manuals