D
Dr. Louis GatesSep 8, 2025
What to do if my Panasonic U-71PZH2E8 smells bad?
- AAndrew NolanSep 8, 2025
The unit inside is dirty and has accumulated odor components. Contact your dealer for assistance.
What to do if my Panasonic U-71PZH2E8 smells bad?
The unit inside is dirty and has accumulated odor components. Contact your dealer for assistance.
Why is my Panasonic Air Conditioner making noise during heating operation?
The noise you hear during heating operation is likely due to the defrost operation being in process.
Why does my Panasonic Air Conditioner fan continue to rotate after I turn it off?
The fan continues to rotate after stopping the Panasonic Air Conditioner with the remote controller for smooth operation.
Why is dust coming out of my Panasonic U-71PZH2E8?
The dust is discharged because it has accumulated inside the indoor unit.
Why does my Panasonic Air Conditioner fan keep rotating for a while even after I stop it?
The fan may continue to rotate to dry the heat exchanger, depending on the setting.
Why does my Panasonic U-71PZH2E8 Air Conditioner smell during operation?
The discharged air smells because indoor odor components, cigarette odor, and cosmetic odor have accumulated in the air conditioner, and this air is being discharged.
Why does the fan keep running after I turn off my Panasonic Air Conditioner?
The fan may continue to rotate after the unit is turned off to dry the heat exchanger, depending on the settings. This is also done to ensure smoother operation.
Why is my Panasonic U-71PZH2E8 making noise during heating?
The noise you are hearing during heating operation is likely due to the defrost operation being in process.
Why is my Panasonic Air Conditioner discharging dust?
Dust discharge may occur if dust has accumulated inside the indoor unit. Ensure that nanoe™ X is set to ON. If nanoe™ X is already ON, it may be considered abnormal, and you should contact your dealer.
Why does my Panasonic U-71PZH2E8 Air Conditioner sound like streaming water?
The sound of streaming water is the sound of refrigerant liquid flowing inside the unit.
Cooling Capacity (kW) | 7.1 |
---|---|
Heating Capacity (kW) | 8.0 |
Refrigerant | R32 |
Cooling Capacity | 7.1 kW |
Heating Capacity | 8.0 kW |
Coefficient of Performance (COP) | 3.61 |
Indoor Unit Weight | 14 kg |
Power Supply | 220-240 V, 50 Hz |
Covers precautions for use, installation, and general safety warnings.
Addresses troubleshooting and steps before requesting service.
Guidance on proper installation procedures and electrical wiring connections.
Common symptoms and causes for indoor and outdoor unit problems.
Troubleshooting steps for non-operation or poor cooling/heating.