Operating Instructions
(Mono bloc) Air-to-Water Heatpump
2-27
Thank you for purchasing Panasonic
product.
Before operating the system, please read these
operating instructions thoroughly and keep them for
future reference.
Installation Instructions attached.
Instrucciones de funcionamiento
Bomba de calor de aire a agua (Mono bloc)
28-53
Gracias por comprar un producto Panasonic.
Antes de utilizar la unidad, sírvase leer atentamente
estas instrucciones de funcionamiento y conservarlas
para futuras consultas.
Instrucciones de instalación adjuntas.
Istruzioni operative
Pompa di calore Aria-acqua (Mono bloc)
54-79
Grazie per aver acquistato un prodotto
Panasonic.
Prima di utilizzare l’unità, leggere attentamente le
istruzioni e conservare questo opuscolo per potervi fare
riferimento in futuro.
Istruzioni per l’installazione allegate.
Gebruiksaanwijzing
(Mono bloc) Air-to-Water Warmtepomp
80-105
Hartelijk dank voor het aanschaffen van een
Panasonic-product.
Lees voor u het apparaat gebruikt deze
gebruikshandleiding grondig en bewaar deze voor
toekomstig gebruik.
De instructies voor installatie zijn bijgevoegd.
ACXF55-14600
Operating Instructions
(Mono bloc)
Air-to-Water Heatpump
Model No.
WH-MDC05H3E5
WH-MDC07H3E5
WH-MDC09H3E5
Model No.
WH-MDC12H6E5
WH-MDC16H6E5
WH-MXC09H3E5
WH-MXC12H6E5
WH-MXC09H3E8
WH-MXC12H9E8
WH-MXC16H9E8
ACXF55-14600_FC0817-0.indb 1ACXF55-14600_FC0817-0.indb 1 7/19/2017 2:05:31 PM7/19/2017 2:05:31 PM

Table of Contents

Other manuals for Panasonic WH-MDC05H3E5

Questions and Answers

  • K
    Kelsey FerrellAug 17, 2025
    Why is my Panasonic WH-MDC05H3E5 Heat Pump system hard to heat up?
    • H
      hollysimmonsAug 17, 2025
      Your Panasonic Heat Pump system may be taking longer to heat up because the panel and floor are being heated simultaneously, which can lower the water temperature and reduce heating ability. Also, low outdoor air temperatures, blockages in the discharge or intake of the mono bloc unit (like snow), or a low preset water outlet temperature can cause this issue.
  • L
    lopezelizabethAug 19, 2025
    Why is my Panasonic Heat Pump system not heating up instantly?
    • D
      Danielle YorkSep 12, 2025
      If your Panasonic Heat Pump starts operating with cold water, it will take some time to heat the water, so immediate heating is not expected.
  • M
    Megan DuffyAug 22, 2025
    How to improve HEAT/COOL mode efficiency on a Panasonic WH-MDC05H3E5 Heat Pump?
    • J
      John SmithAug 22, 2025
      To improve the efficiency of your Panasonic Heat Pump's HEAT/COOL mode, set the temperature correctly, close the panel heater/cooler valve, and clear any obstructions in the air inlet and outlet vents of the mono bloc unit.
  • S
    stephen46Aug 25, 2025
    Why is COOL mode unavailable on my Panasonic WH-MDC05H3E5 Heat Pump?
    • M
      Matthew HardyAug 26, 2025
      The COOL mode on your Panasonic Heat Pump might be unavailable because the system is locked to operate only in HEAT mode.
  • A
    aaron26Aug 27, 2025
    Why does my Panasonic WH-MDC05H3E5 operation start automatically?
    • T
      Tara AndradeAug 27, 2025
      If your Panasonic Heat Pump starts operating automatically even when the timer isn't set, check if the sterilization timer has been activated.
  • K
    Kimberly MurrayAug 30, 2025
    Why is the backup heater turning on automatically on my Panasonic WH-MDC05H3E5?
    • D
      Danielle CooperAug 30, 2025
      The backup heater in your Panasonic Heat Pump might automatically turn on, even when disabled, due to the protection control of the unit's heat exchanger.
  • L
    Laura TorresSep 2, 2025
    Why does my Panasonic WH-MDC05H3E5 make loud refrigerant noises?
    • T
      Timothy BruceSep 2, 2025
      The loud refrigerant noise in your Panasonic Heat Pump is caused by protection control during de-icing when the outdoor temperature is below -10 °C.
  • J
    Jacqueline MartinezSep 4, 2025
    Why does my Panasonic WH-MDC05H3E5 Heat Pump mono bloc unit emit water or steam?
    • G
      gwernerSep 4, 2025
      The emission of water or steam from your Panasonic Heat Pump mono bloc unit is due to condensation or evaporation occurring in the pipes.
  • R
    Ryan HillSep 7, 2025
    Why does steam come out of my Panasonic WH-MDC05H3E5?
    • S
      stevenmarshSep 7, 2025
      Steam coming from the Panasonic Heat Pump mono bloc unit during heating mode is due to the defrost operation in the heat exchanger.
  • E
    Edward TylerSep 10, 2025
    Why does my Panasonic Heat Pump make a water flowing sound?
    • D
      David DudleySep 10, 2025
      The water flowing sound you hear during the operation of your Panasonic Heat Pump is due to the refrigerant flow inside the unit.