Item Unit Outdoor Unit
Power Source (Phase, Voltage, Cycle)
ø Single
V 230
Hz 50
Input Power
Condition
(Ambient/Water)
A35W7 A7W35 A2W35
kW Cooling: 1.04 Heating: 0.64 Heating: 0.90
Maximum Input Power For Heatpump System kW 2.59
Power Supply 1 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 1Ø / 12.0 / 2.59k
Power Supply 2 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 1Ø / 13.0 / 3.00k
Power Supply 3 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) — / — / —
Starting Current A 3.0
Running Current
Condition
(Ambient/Water)
A35W7 A7W35 A2W35
A Cooling: 4.8 Heating: 3.0 Heating: 4.2
Maximum Current For Heatpump System A 12.0
Power Factor
Power factor means total figure of compressor and
outdoor fan motor.
%
Cooling: 94
Heating: 93
Power Cord
Number of core -
Length m (ft) -
Thermostat Electronic Control
Protection Device Electronic Control
Item Unit Indoor Unit
Performance Test Condition EN 14511
Operation Range
Outdoor Ambient °C (min. / max.)
Cooling: 16 / 43
Heating: -20 / 35
Water Outlet °C (min. / max.)
Cooling: 5 / 20
Heating (Tank): - / 65*, Heating (Circuit): 20 / 55
Internal Pressure Differential kPa
Cooling: 5.0
Heating: 5.0
Noise Level
Condition
(Ambient/Water)
A35W7 A7W35 A2W35
dB (A) Cooling: 28 Heating: 28
Power Level dB Cooling: 41 Heating: 41
Dimension
Height mm (inch) 717 (28-7/32)
Width mm (inch) 598 (23-17/32)
Depth mm (inch) 1800 (70-27/32)
Net Weight kg (lbs) 120 (265)
Refrigerant Pipe Diameter
Liquid mm (inch) 6.35 (1/4)
Gas mm (inch) 12.70 (1/2)
Water Pipe Diameter
Room mm (inch) 28 (1-3/32)
Shower mm (inch) 19 (3/4)
Water Drain Hose Inner Diameter mm (inch) 12 (17/36)
Pump Zone 1
Motor Type DC Motor
No. of Speed 7 (Software Selection)
Input Power W 42
Hot Water Coil
Type Brazed Plate
No. of Plates 48
Size (W x H x L) mm 93 × 82 × 325
Water Flow Rate l/min (m
3
/h)
Cooling: 9.2 (0.6)
Heating: 9.2 (0.6)
Pressure Relief Valve Water Circuit kPa Open: 300, Close: 265 and below
Flow Switch
Type Magnetic Lead Switch
Set Point l/min 6.7
Pressure Release Valve kPa Open: 1150±200, Close: 700 and below
Protection Device A Residual Current Circuit Breaker (30)