EasyManua.ls Logo

Panasonic WH-UD09JE5 Series - Heat Mode - Water Temperature Settings

Panasonic WH-UD09JE5 Series
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30
Menus
For installer
Menu Default Setting Setting Options / Display
Water temp. for heating ON Compensation curve
X axis: -5 °C, 15 °C
Y axis: 55 °C, 35 °C
Input the 4
temperature points
(2 on horizontal X
axis, 2 on vertical Y
axis).
Temperature range: X axis: -20 °C ~ 15 °C, Y axis: See below
Temperature range for the Y axis input:
1. WH-UD model: 20 °C ~ 60 °C
2. WH-UH model & Back up heater is enabled: 25 °C ~ 65 °C
3. WH-UH model & Back up heater is disabled: 35 °C ~ 65 °C
4. WH-UX model: 20 °C ~ 60 °C
If 2 zone system is selected, the 4 temperature points must also be input for Zone
2.
“Zone 1” and “Zone 2” will not appear on the display if only 1 zone system.
Water temp. for heating ON Direct
35 °C
Temperature for
heating ON
Min. ~ Max. range is conditional as follows:
1. WH-UD model: 20 °C ~ 60 °C
2. WH-UH model & Back up heater is enabled: 25 °C ~ 65 °C
3. WH-UH model & Back up heater is disabled: 35 °C ~ 65 °C
4. WH-UX model: 20 °C ~ 60 °C
If 2 zone system is selected, temperature set point must input for Zone 2.
“Zone 1” and “Zone 2” will not appear on the display if only 1 zone system.
Outdoor temp. for heating OFF
24 °C
Temperature for
heating OFF
T for heating ON
5 °C
Set
T for heating
ON.
* This setting will not
available to set when
pump owrate set to
Max. duty.
Heater ON/OFF
Heater ON/OFF Outdoor temp. for heater ON
0 °C