Shutter/dissolver motor jammed. Use manual knob to un-jam shutter or bypass.
Mirror/shutter motor not locked to speed. Inch mirror and check for tightness.
Movement motor not locked to speed. Inch movement, check tightness, clean and oil.
Magazine take-up motor jammed. Ensure film path is clear and check magazine lock.
Bad external speed control clock signal. Check ACC cable and speed setting.
Focus/Iris/Zoom motor jammed or overheated. Check motor bracket for gear binding.
Displays camera speed and elapsed film in feet, meters, or frames.
Adjustable display brightness via up and down buttons.
Shows the current battery voltage.
Displays internal temperature in Fahrenheit or Celsius.
Shows current speed and shutter angle settings, allowing custom speed setup.
Select English/Metric units using up/down buttons.
Select 4, 3, or 2 perf film using up/down buttons.
Displays camera, CPU, DSP, Xilinx, Epan, Magazine, and Panel software versions.
Camera internal temp below 50°F/10°C. Connect 24v battery to heater.
Battery voltage is 21v or lower. Replace weak battery.
FTZ motor driver damaged or bad connection. Contact Panavision.
Film jammed in movement. Camera will not run. Clear the jam.
Film magazine is near empty or empty. Camera stops.
Camera door is open. Ensure door is securely latched.
FPS or shutter angle entry is invalid. Re-enter desired value.
Indicates a behind-the-lens filter is in use.
Toggle between phase-out mode (streaking) and normal mode.
Display blank or cycling on/off may indicate a bad battery.