10
Programming Guide
06 = Arm/Disarm with Remote Control 01-08 = Remote Controls 1 to 8
99 = Any Remote Control
07 = Button Pressed on Remote (see
button option “B” on page27)
01-08 = Remote Controls 1 to 8
99 = Any Remote Control
08 = Button Pressed on Remote (see
button option “C” on page27)
01-08 = Remote Controls 1 to 8
99 = Any Remote Control
09 = Button Pressed on Remote (see
button option “D” on page27)
01-08 = Remote Controls 1 to 8
99 = Any Remote Control
10 = Bypass Programming 01-48 = User Code Numbers 001 to 048
99 = Any User Code
11 = User Activated PGM 01-48 = User Code Numbers 001 to 048
99 = Any User Code
12 = Zone with Delay Transmission
Option Enabled is Breached
01-16 = Zones 1 to 16
99 = Any Zone
13 = Arm with User Code 01-48 = User Code Numbers 001 to 048
99 = Any User Code
14 = Special Arm 00 = Auto Arming (timed/no movement)
01 = Late to Close (auto arming failed)
02 = No Movement Auto Arming
03 = Partial Arming (stay, force, instant, bypass)
04 = One-Touch Arming
05 = Arm with WinLoad Software
06 = Arm with Keyswitch
99 = Any Sub-Group
15 = Disarm with User Code 01-48 = User Code Numbers 001 to 048
99 = Any User Code
16 = Disarm After Alarm w/ User Code 01-48 = User Code Numbers 001 to 048
99 = Any User Code
17 = Cancel Alarm with User Code 01-48 = User Code Numbers 001 to 048
99 = Any User Code
18 = Special Disarm 00 = Cancel Auto Arm (timed/no movement)
01 = Disarm with WinLoad Software
02 = Disarm with Keyswitch
03 = Reserved for Future Use
04 = Disarm after alarm with WinLoad Software
05 = Disarm after alarm with Keyswitch
06 = Cancel Alarm with WinLoad Software
07 = Cancel Alarm with Keyswitch
99 = Any Sub-Group
19 = Zone Bypassed on Arming 01-16 = Zones 1 to 16
99 = Any Zone
20 = Zone in Alarm 01-16 = Zones 1 to 16
99 = Any Zone
21 = Fire Alarm 03 = Zone 3
99 = Any Zone
22 = Zone Alarm Restore 01-16 = Zones 1 to 16
99 = Any Zone
23 = Fire Alarm Restore 03 = Zone 3
99 = Any Zone
Event Group # Sub-Group #

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Spectra 1728EX and is the answer not in the manual?

Paradox Spectra 1728EX Specifications

General IconGeneral
BrandParadox
ModelSpectra 1728EX
CategoryControl Panel
LanguageEnglish

Related product manuals