PARAGON 2000 Plus Installation Instructions
SECTION FIVE Specification
NATURAL GAS PROPANE GAS
Category of Appliance: B
AS
B
AS
Category I
2H
I
3P
Gas type: G20 G31
Gas Pressure: 20 mbar 37 mbar
Gas input high: 7.00 kW Gross 7.00 kW Gross
Gas input low: 2.40 kW Gross 2.40 kW Gross
Injector Main: Size 460A Size 135
Oxy-pilot SIT9040 SIT9222
Data Label Location: Behind trim
Gas Connection: 8 mm OD Tube
NOTE: The efficiency of this appliance has been measured as specified in BS7977-1 2009
and the result is 55.6%. The gross calorific value of the fuel has been used for this
efficiency calculation. GASTEC have certified the test data from which it has been
calculated. The efficiency value may be used in the UK Government’s Standard
Assessment Procedure (SAP) for energy rating of dwellings.
SECTION SIX Regulations and Warnings
THIS APPLIANCE MUST ONLY BE INSTALLED IN THE GB OR IRELAND.
Only to be used in sufficiently ventilated room. Read instructions carefully before
installation and use. The appliance must be installed by a competent person, i.e.. Gas
Safe Registered Installer in accordance with the current Gas Safety (Installation and
Use) Regulations 1998 (as amended). Failure to do so could lead to prosecution.
This PARAGON 2000 Plus is for use ONLY with the GAS STATED ON THE DATA
BADGE this may be G20 for Natural Gas or G31 for Propane Gas CHECK YOU HAVE
THE CORRECT APPLIANCE FOR THE GAS YOU ARE USING.
It can be used in conjunction with the following chimneys: -
A conventional brick or stone chimney,
A pre-cast flue conforming to BS 1289 Pt. 1 or Pt. 2
A metal flue and box conforming to BS 715, further details are covered in later text.