• Inspect blower mounting, driveline, PTO and air filter for integrity.
•
Verify melt plugs are intact - replace as needed prior to operation.
• Remove camlock dust cap and connect the hot air hose.
• Follow trailer manufacturers recommendation regarding product hose connection and valve operation.
• Slowly engage PTO with engine at idle.
• Bring up to operating speed and lock engine at recommended speed (shown in cab).
• Unload trailer as per trailer manufacturer’s recommendation and do not exceed maximum tank pressure.
• While discharging, visually check blower for vibration, mechanical noise or excessive heat.
• If relief valve is operating adjust proportioning valve to reduce tank pressure.
• Reduce pressure to zero as per trailer manufacturers instructions.
• Disengage PTO (No cool down period required).
• Disconnect blower hose and replace camlock dust cap.
Caution:
- The blower and accessories will become hot enough to cause serious skin burns on contact.
- Rotating machinery is dangerous.
- Always wear ear protection when in close proximity to blower.
Standard Oil: P858/P1057 oil (Paragon part number: 409-002)
Caution: Mixing or incorrect oil can result in gear and
bearing failure.
A good maintenance program will keep your P858/P1057 blower in top running condition. A newly installed P858/
P1057 blower should be checked frequently during the first month of operation, especially lubrication. Check oil levels
and add as needed. Complete oil changes are recommended every 500 operating hours, or more frequently (An oil
analysis program is recommended). Below is Paragon’s recommended minimum maintenance program.