EasyManua.ls Logo

Parkside PTPU 1500 A1 - User Manual

Parkside PTPU 1500 A1
145 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
OS
IAN 388427_2107
POMPA DO OCZKA WODNEGO
Wskazówki dotyczące montażu, obsługi i bezpieczeństwa
Tłumaczenie oryginalnej instrukcji eksploatacji
JEZÍRKOVÉ ČERPADLO
Návod k obsluze a bezpečnostní pokyny
Originální návod k obsluze
CZ
PL
BOMBA PARA ESTANQUES
Instrucciones de funcionamiento y de seguridad
Traducción del manual de funcionamiento original
JAZIERKOVÉ ČERPADLO
Návod na obsluhu a bezpečnostné upozornenia
Originálny návod na obsluhu
SK
ES
ČRPALKA ZA RIBNIK
Navodila za upravljanje in varnostna opozorila
Prevod originalnega navodila za uporabo
KERTITÓ-SZIVATTYÚ
Kezelési és biztonsági hivatkozások
Az eredeti használati utasítás fordítása
HU
SI
TEICHPUMPE
Bedienungs- und Sicherheitshinweise
Originalbetriebsanleitung
POND PUMP
Operation and Safety Notes
Translation of the original instructions
GB
IE NI CY
MT
DE AT
VIJVERPOMP
Bedienings- en veiligheidsinstructies
Vertaling van de originele bedieningshandleiding
POMPE POUR BASSIN
Consignes d’utilisation et de sécurité
Traduction du mode d’emploi d‘origine
FR
BE CH NL BE
POMPA PER LAGHETTO
Istruzioni di montaggio, utilizzo e sicurezza
Traduzione delle istruzioni d’uso originali
BASSINPUMPE
Brugs- og sikkerhedsanvisninger
Oversættelse af den originale driftsvejledning
DK
IT
MT
CH
CH
POND PUMP PTPU 1500 A1
TEICHPUMPE PTPU 1500 A1
POMPE POUR BASSIN PTPU 1500 A1

Table of Contents

Questions and Answers

  • S
    Susan MillerAug 11, 2025
    What to do if my Parkside Pond Pump 1 stops running?
    • D
      Dillon MurphyAug 11, 2025
      If your Parkside Pond Pump 1 isn't running, there could be a couple of reasons: * The power supply might be interrupted. Ensure the mains plug 2 is securely plugged in. * There might be a cable breakage. In this case, it's best to have the cable and pump 1 checked by a qualified service point.
  • P
    parksrebeccaAug 20, 2025
    Why does my Parkside Pond Pump have insufficient pumping capacity?
    • W
      William MaldonadoAug 21, 2025
      Insufficient pumping capacity in your Parkside Pond Pump may be due to: * The housing being clogged with dirt. Clean the pump 1 according to the instructions in the “Maintenance and cleaning” chapter. * Heavy loss in the pipes. Check for leaks, excessive height differences, and kinked hoses.
  • L
    Lori BatesAug 30, 2025
    Why does my Parkside Pond Pump 1 switch off quickly?
    • R
      Ronald HarrisAug 30, 2025
      If your Parkside Pond Pump 1 switches off after a short time, it could be due to: * Excessive contaminated water. Clean the pump 1 and fit a filter in the system. * Excessive water temperature. Make sure the water temperature does not exceed 35 °C.

Parkside PTPU 1500 A1 Specifications

General IconGeneral
Power1500 W
Max Flow Rate15000 L/h
Max Head8 m
Cable Length10 m
Weight1.78 kg
Power consumption1500 W
Maximum flow rate15000 L/h
Maximum immersion depth7 m
Protection typeIPX8
Voltage230 V
Frequency50 Hz