RW500U
PIR Occupancy Sensor Switch
with Manual
ON/OFF
Limited FIVE YEAR Warranty
Pass & Seymour/Legrand will remedy any defect in workmanship or material in Pass & Seymour/Legrand prod-
ucts which may develop under proper and normal use within five years from the date of purchase by a consumer:
(1) by repair or replacement, or, at Pass & Seymour/Legrand’s option, (2) by return of an amount equal to the
consumer’s purchase price. Such remedy is IN LIEU OF ANY AND ALL EXPRESSED OR IMPLIED WARRANTIES
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Such remedy by Pass & Seymour/Legrand
does not include or c
o
v
er cost of labor for removal or reinstallation of the product. ALL OTHER FURTHER ELE-
MENTS OF DAMAGE (INCIDENTAL OR CONSEQUENTIAL DAMAGES) FOR BREACH OF ANY AND ALL EXPRESSED
OR IMPLIED WARRANTIES including warr
anties OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PUR-
POSE ARE EX
CL
UDED HEREBY
. (Some s
t
ates do not allow disclaimer or exclusion or limitation of incidental or
consequential damages, so the above disclaimers and limitation or exclusion may not apply to you.) ANY IMPLIED
W
ARRANTIES INCLUDING WHERE REQUIRED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTIC-
ULAR PURPOSE SHALL BE LIMITED T
O THE FIVE YEAR PERIOD SET F
ORTH ABO
VE. (Some s
t
at
es do not allow
limitation on how long an implied warranty lasts, so the above limitation may not apply to you.)
To ensure safety, all repairs to Pass & Seymour/Legrand products must be made by Pass & Seymour/Legrand
or under its specific dir
ection. Procedure to obtain performance of any warranty obligation is as follows:
(1) Contact P
ass & Se
ymour/Legr
and, P.O. Box 4822, Syracuse, NY 13221 for instructions concerning return
or repair; (2) return the product to Pass & Seymour/Legrand, postage paid, with your name and address and a
writt
en description of the installation or use of the Pass & Seymour/Legrand product, and the observed defects
or f
ailure t
o oper
at
e, or other claimed basis for dissatisfaction.
This warranty giv
es y
ou specific l
egal rights and you may also have other rights which vary from state to state.
Please read all instructions before installing
Installation Instructions
Lens
Lighted Switch
ON/OFF Button
Syracuse, NY 13221
SPECIFICATIONS
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120VAC, 60Hz
Load (Single Pole Circuit)
Incandescent . . . . . . . . . . . . . . . . . . . . . . . . . . 25-500 Watts
Time Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 minutes
Environment . . . . . . . . . . . . . . . . .Residential Indoor use only
Operating Temperature . . . . . . . .32° to 131°F (0° to 55°C)
Humidity . . . . . . . . . . . . . . . . . . . .95% RH, non-condensing
Electrical Supply Wire . . .minimum temp rating 167°F (75°C)
Tools Needed:
Insulated Screwdriver
Wire Strippers
P.O. Box 4822, Syracuse, NY 13221-4822
Technical Support: 800.223.4185 • www.passandseymour.com
340800 Rev. B 08129
Visit our website at: www.passandseymour.com
TEST MODE
To test the detection coverage:
During the TEST mode, the controlled load turns ON for 5 seconds each time the
sensor detects occupancy.
1. Press and hold the ON/OFF button. After 10 seconds the lighted switch turns
OFF. The controlled load turns ON if it was not already ON. The sensor is now
in a TEST mode that lasts 5 minutes. (You can end the TEST mode sooner by
pressing the ON/OFF button for another 10 seconds).
2. Move out of the coverage area or stand very still. The controlled load turns
OFF after 5 seconds if no motion is detected.
3. Move into the coverage area. The controlled load turns ON for 5 seconds each
time the sensor detects motion. After 5 seconds expire without motion
detection, the load turns OFF. The controlled load turns ON automatically with
the next motion detection and stays ON for 5 seconds.
4. Repeat as necessary to ensure that the desired coverage areas are within
detection range.
TROUBLESHOOTING
Load will not turn ON (lighted switch is visible):
• Move in front of the sensor to automatically turn lights ON. If lights do not
turn ON, press the ON/OFF button. The lighted switch should turn OFF and
the controlled load should turn ON, if not:
• Check the light bulb.
• Turn OFF power to the circuit then check wire connections.
• Remember that if the load is turned OFF manually, Automatic-ON is
reenabled only after no motion is detected for 5 minutes.
Light will not turn ON (lighted switch is NOT visible):
• Check the light bulb.
• Make certain that the circuit breaker is ON and functioning.
• Turn OFF power to the circuit then check wire connections.
Load will not turn OFF:
The time delay is 5 minutes (fixed time delay).
• Make sure no motion occurs in the coverage area until the time delay
expires.
• If the load does not turn OFF, call Technical Support at 800.223.4185.
• Hot air currents and heat radiant devices can cause false detection. Make
sure the sensor is at least 6 feet (2 meters) away from devices that are a
significant heat source (e.g heater, heater vent, high wattage light bulb).
• Press the ON/OFF button. If the controlled load does not turn OFF, turn
OFF the power to the circuit, then check wire connections.
340800_RevB_IS_12266 4/23/07 9:55 AM Page 1