Explains the connection of the fence ground terminal to the ground system.
Explains the connection of the fence output terminal to the fence.
Warns of electric shock and requires repair by qualified personnel only.
Connects the fence ground terminal to a separate ground system and the output terminal to the fence.
Selects a suitable site for the ground system, at least 33' from other systems.
Advises switching off the unit before work and reading all safety considerations.
Prohibits unsupervised use by young or infirm persons, and children playing near fences.
Prohibits electrifying barbed wire and mandates offset wires be 6" from it.
Advises against fence constructions causing entanglement and limits offset wires.
Discourages supplying from two units and mandates 8' spacing for adjacent wires.
Specifies placement of ground electrode at least 33' from power/telecom systems.
Specifies the unit is not for persons with reduced capabilities without supervision.
Emphasizes supervising children to ensure they do not play with the unit.
States fences must not be supplied from two separate units or independent circuits.
Mandates at least 8' (2.5m) spacing for wires from separate electric animal fences.
Prohibits electrifying barbed or razor wire, but allows use for support.
Specifies offset electrified wires must be 6" from non-electrified wires.
Requires 33' (10m) separation between ground electrode and other grounding systems.