EasyManua.ls Logo

Patriot PW 120 - User Manual

Patriot PW 120
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
EN ELECTRIC HIGH-PRESSURE CLEANER COLD WATER
CZ ELEKTRICKÝ VYSOKOTLAKÝ ČISTIČ BEZ OHŘEVU VODY
SK ELEKTRICKÝ VYSOKOTLAKOVÝ ČISTIČ BEZ OHREVU VODY
Patriot PW 120
MODEL YLQ5660G-140A
Instruction manual for use and maintenance
Návod k použití a údržbě
vod na použitie a údržbu
Warning!
Do not operate the machine before reading this instruction manual!
Upozornění!
Nepoužívejte zařízení, dokud jste si nepřečetli návod k použití a údržbě!
Upozornenie!
Nepoužívajte zariadenie bez prečítania jeho návodu na použitie a údržbu!
2020 - 02

Questions and Answers

  • K
    Kelly JohnsonAug 16, 2025
    Why is there a loss of pressure in my Patriot Ultrasonic Jewelry Cleaner?
    • J
      james36Aug 16, 2025
      A loss of pressure in your Patriot Ultrasonic Jewelry Cleaner can occur due to several reasons: * The nozzle is worn, so you should change it. * The valves are dirty or clogged; check, clean, or replace them. * The valve seals are worn; check and/or replace them. * The seals are worn; check and/or replace them. * The filter is clogged; check and/or clean it.
  • T
    Tiffany ParrishAug 19, 2025
    How to reduce excess noise from Patriot PW 120 Ultrasonic Jewelry Cleaner?
    • Y
      Yolanda GregoryAug 19, 2025
      Excess noise from your Patriot Ultrasonic Jewelry Cleaner may be due to: * Air being drawn in; check the intake lines. * Worn, dirty, or clogged valves; check, clean, or replace them. * Worn bearings; check and/or replace them. * Water temperature being too high; lower the temperature to below 40 °C. * A dirty filter; check and/or replace it.
  • A
    Amanda AdamsAug 22, 2025
    What to do if the Patriot Ultrasonic Jewelry Cleaner pump doesn't run when the switch is pressed?
    • A
      Ashley SchwartzAug 22, 2025
      If the pump of your Patriot Ultrasonic Jewelry Cleaner doesn't run, here are a few things to check: * Inspect the plug and fuses for damage. * Verify that the voltage is sufficient. * Manually turn over the motor if the pump is locked. * Allow the motor to cool down if the thermal relay has triggered.
  • K
    Kimberly DavisAug 25, 2025
    Why is my Patriot PW 120 pump running but not generating pressure?
    • B
      bshortAug 26, 2025
      If the pump in your Patriot Ultrasonic Jewelry Cleaner runs but no pressure is generated, consider the following: * The intake filter may be clogged; clean it. * Air may be drawn in at the connectors; check the intake connection fitting and the hose connectors. * The inlet and outlet valves may be clogged or worn; clean or replace them. * The diameter of the nozzle hole may be too large; check and replace it.
  • M
    Mary ShepherdAug 28, 2025
    Why does the motor on my Patriot Ultrasonic Jewelry Cleaner suddenly stop?
    • M
      Matthew SimsAug 28, 2025
      If the motor on your Patriot Ultrasonic Jewelry Cleaner suddenly stops, it could be due to the thermal relay being triggered by overheating. Check the voltage, turn off the switch, and let the motor cool down for a few minutes.
  • G
    Gary ThomasAug 31, 2025
    What causes irregular operating pressure in my Patriot PW 120 Ultrasonic Jewelry Cleaner?
    • A
      alicia28Aug 31, 2025
      Irregular operating pressure in your Patriot Ultrasonic Jewelry Cleaner could be caused by: * Air being drawn in; check the intake connectors. * Clogged and worn valves; clean and replace them. * Worn seals; check and replace them. * The motor not stopping completely when previously letting go of the gun trigger; wait for the motor to stop completely before pressing the trigger again.
  • D
    Diane JohnsonSep 3, 2025
    What to do if my Patriot Ultrasonic Jewelry Cleaner motor hums but doesn't start when the switch is pressed?
    • T
      Travis GonzalesSep 3, 2025
      If the motor of your Patriot Ultrasonic Jewelry Cleaner hums but doesn't start when the switch is pressed: * Check the voltage; the mains voltage might be lower than specified. * Check the pump; it might be blocked or frozen. * Check to see that the extension cable is sufficient. Exchange the extension cable for one that is sufficient, if it is not.
  • J
    Joseph MooreSep 6, 2025
    Why is my Patriot PW 120 Ultrasonic Jewelry Cleaner pump dripping?
    • A
      Allen PattonSep 6, 2025
      If your Patriot Ultrasonic Jewelry Cleaner pump is dripping, it is likely that the seals are worn. Check and replace them, if needed (professional repair shop).
  • A
    allisonwilliamsSep 9, 2025
    Why is water leaking from the pump head of my Patriot Ultrasonic Jewelry Cleaner?
    • J
      Jessica WrightSep 9, 2025
      If water is leaking from the pump head of your Patriot Ultrasonic Jewelry Cleaner, it could be due to worn seals or a worn O-ring of the seal set. Exchange the seal or the O-ring.
  • V
    vmarshallSep 12, 2025
    Why is the water expelled from my Patriot PW 120 mixed with oil?
    • C
      Chad GreenSep 12, 2025
      If the water expelled from your Patriot Ultrasonic Jewelry Cleaner is mixed with oil, the sealing rings (water + oil) are likely worn. Check and/or replace them.

Summary

Technical Specifications

Electrical and Performance Data

Details about voltage, power, pressure, flow rate, and sound levels.

List of Parts

Identification of all components with corresponding numbers.

Used Symbols and Pictograms

Safety Information

Signal Words and Risk Levels

Explains the meaning of 'Danger', 'Warning', and 'Caution' signal words.

General Safety Regulations

Essential rules for safe operation and preventing accidents.

Electrical Setup and Safety

Mains Power Connection

Guidelines for connecting the high-pressure washer to the main electrical supply.

Extension Cord Usage

Requirements for extension cords, including length and cross-section for safe outdoor use.

Electrical Shock Hazard Warnings

Information on preventing electrical shock, proper grounding, and modifying plugs.

Product Description, Safety Features, and Assembly

Purpose, Application, and Safety Devices

Outlines intended use, application areas, usage limits, and safety device functions.

Assembly Instructions

Step-by-step guide for attaching handle, hose hooks, spray wand, and hose.

Start-up and Operation

Water Supply and Pump Priming

Instructions for connecting water, drawing from reservoirs, and bleeding the pump.

High Pressure Operation Safety

Cautionary advice on maintaining safe distances during high-pressure cleaning.

Using the Lance and Nozzle

Spray Adjustment and Detergent Use

How to adjust water spray, pressure modes, and apply detergent.

Operational Workflow

Preparation and Trigger Control

Steps for securing the washer, connecting supplies, and managing the trigger and kickback.

Detergent Operation and Cleaning

Detergent Application and Methods

How to use detergent, recommended cleaning, and post-use care.

Operation Interruption, Shutdown, and Water Turn-off

Pausing, Finishing, and Disconnecting

Procedures for safely interrupting, finishing operations, and turning off supplies.

Transportation and Storage

Transporting by Hand

Instructions for safely carrying the appliance manually.

Transporting in Vehicles

Guidelines for securing and moving the appliance in a vehicle.

Storing the Appliance

Steps for proper storage, including securing parts and temperature.

Protection, Maintenance, and Disposal

Frost Protection and Routine Maintenance

Measures to protect against frost and perform regular cleaning of filters and nozzles.

Environmental Disposal Guidelines

Instructions for making the machine unusable and responsible recycling.

Warranty Service

Warranty Terms and Conditions

Information on product manufacturing quality and warranty period.

Warranty Exclusions

Lists parts and conditions not covered by the warranty.

Troubleshooting Guide

Patriot PW 120 Specifications

General IconGeneral
ModelPW 120
Ultrasonic Frequency42 kHz
Heating FunctionNo
Dimensions200 x 140 x 125 mm
MaterialStainless Steel