Ins-150 Date code: 161002
Net2 quickstart installation guide
About
This document is a brief guide to installing and commissioning a Net2 system. If you are new to Net2 please
read through the Net2 installation reference manual before attempting installation!
Wiring
Power
supply
1
2
3
4
5
6
7
8
9
0
ABC
DEF
GHI JKL
MNO
PQR
ST UV
WX
YZ
Tamper Switch
Exit Button
12V d.c.
alarm sounder
Normally closed
door contact
Fail Closed
electric release
Unswitched
spur
12V d.c
power
supply
CARDLOCK reader
Membrane or
stainless steel
keypad
From
previous
ACU
To next ACU
NETWORK CABLE
Refer to network
wiring instructions
Red
Brown
Orange
Green
Yellow
Blue
Mauve
Black/White
Brown
Yellow
Reader 1
PAXTON
ACCESS
Simple & Powerful
Orange
Keypad 1
+12v
0v
N.C.
N.O.
Com
N.C.
N.O.
Com
Alarm Output
0v
Contact
0v
Exit
0v
Tamper
PSU
Rx
Tx
Relay 1
Relay 2
Exit
Contact
Tamper
PSU
OK
5v
12v
Red
Brown
Orange
Green
Yellow
Blue
Mauve
Black/White
Brown
Yellow
Orange
Reader 2
Keypad 2
Power
Relay 1Relay 2Inputs
Net2
1 Door
Access Control Unit
Network
CAT5 cable coding
White/Green
Green
White/Orange
Orange
1
2
3
4
Screen or spare cores
from network cable
IMPORTANT: the red wire on
Paxton Slimline, Vandal proof,
Back box and Panel mount
PROXIMITY readers must be
connected to the +12V terminal
PROXIMITY reader
What data cable should be used?
The hardware has been improved to accommodate using Category 5 (CAT5) cable for networking the Net2
controllers. The network labelling has been changed to reflect this. It is still OK to use Beldon 8723 cable.
Cable core ACU RS485/232 Old network labelling
White/Green 1 1 OUT-B
Green 2 2 OUT-A
White/Orange 3 3 IN-A
Orange 4 4 IN-B
Things to look out for when wiring:
Are the end of line termination resistors in place?
Are the reader and data cable screens connected throughout?
(Reader and keypad screens should be connected to the Blk/Wht terminal)
Note about wirin
g
ke
y
pads: A 220Ohm resistor must be wired in series with the
g
reen cable core. The
resistor is supplied in the keypad fitting kit.
Table showin
g
data
cable connections
Question and Answer IconNeed help?

Do you have a question about the Paxton Access Net2 and is the answer not in the manual?

Paxton Access Net2 Specifications

General IconGeneral
CommunicationTCP/IP
Max Number of Users10, 000
Power Supply12V DC
CategoryIP Access Controllers
ManufacturerPaxton Access
Product NameNet2
Max Doors2
Max Events50000
Product TypeIP Access Controller

Summary

About Net2 Quickstart Guide

Wiring

Keypad Wiring Note

A 220 Ohm resistor must be wired in series with the green cable core for keypad installation.

Data Cable Specification

Recommends CAT5 cable for Net2 networking and lists cable core to ACU/RS485 mapping.

Commissioning

ACU Configuration

Details naming the ACU, setting door open times, and configuring reader/keypad types.

System Verification

Verifies system functionality by creating events and checking their appearance in the Events screen.

Using the System

Initial System Setup

Guides on changing passwords, setting time zones, access levels, and adding users.

Technical Helpline