Operaon Systems, Luxury Series | SmartTouch™ Control
37
Sengs Screen
Heat Mode—Ready vs. Rest
In order for the spa to heat, a pump needs to circulate water through the heater. The pump that performs this funcon is known as
the “heater pump.”
The heater pump is a 2-Speed Pump 1, Ready Mode will circulate water every 1/2 hour, using Pump 1 Low, in order to maintain a
constant water temperature, heat as needed, and refresh the temperature display. This is known as “polling.”
Rest Mode will only allow heang during programmed filter cycles. Since polling does not occur, the temperature display may not
show a current temperature unl the heater pump has been running for a minute or two.
When the heater pump has come on automacally (for example for heang) you can switch between low speed and high speed but
you cannot turn the heater pump off.
Ready-in-Rest Mode
Ready in Rest Mode appears in the display if the spa is in Rest Mode and the Jets 1 Buon is pressed. When the heater pump has
come on automacally (for example for heang) you can switch between low speed and high speed but you cannot turn the
heater pump off. Aer 1 hour, the System will revert to Rest Mode. This mode can also be reset by selecng the Heat Mode line.
Sengs
Programming, Etc.
The Sengs Screen is where all programming and other spa behaviors are controlled.
Each icon on the Sengs screen takes you to a dierent screen, where one or more seng may be viewed and/or edited.
The Heat Icon takes you to a screen where you control the Heat Mode and the Temperature Range.
Dual Temperature Ranges (High vs. Low)
This system incorporates two temperature range sengs with independent set temperatures. The specific range can be selected on
the Sengs screen and is visible on the Main Screen in the upper le corner of the display.
These ranges can be used for various reasons, with a common use being a “ready to use” seng vs. a “vacaon” seng. Each range
maintains its own set temperature as programmed by the user. This way, when a range is chosen, the spa will heat to the set
temperature associated with that range.
High Range can be set between 80°F and 104°F. Low Range can be set between 50°F and 99°F. Freeze Protecon is acve in either
range.