Operaon Systems, Luxury Series | SmartTouch™ Control
43
General
Most messages and alerts will appear at the boom of the normally used screens. Several alerts and messages may be displayed in
a sequence.
Water Temperature is Unknown
Aer the pump has been running for 1 minute, the temperature will be displayed
– – – –°F – – – –°C
Possible Freezing Condion
A potenal freeze condion has been detected. All water devices are acvated. In some cases,
pumps may turn on and off and the heater may operate during Freeze Protecon. This is an
operaonal message, not an error indicaon.
The Water is Too Hot—M029*
The system has detected a spa water temp of 110°F (43.3°C) or more, and spa funcons are disabled. System will auto reset when
the spa water temp is below 108°F (42.2°C). Check for extended pump operaon or high ambient temp.
Heater Related
The Water Flow is Low—M016*
There may not be enough water flow through the heater to carry the heat away from the heang element. Heater start up will
begin again aer about 1 min. See “Flow Related Checks” below.
The Water Flow had Failed* - M017*
There is not enough water flow through the heater to carry the heat away from the heang element and the heater has been
disabled. See “Flow Related Checks” below. Aer the problem has been resolved, reset the message*.
The Heater may be Dry* - M028**
Possible dry heater, or not enough water in the heater to start it. The spa is shut down for 15 min. Reset this message* to reset the
heater start-up. See “Flow Related Checks” below.
The Heater is Dry* - M027**
There is not enough water in the heater to start it. The spa is shut down. Aer the problem has
been resolved, you must reset the message* to restart heater start up. See “Flow Related
Checks” below.
The Heater is Too Hot* - M030**
One of the water temp sensors has detected 118°f (47.8°C) in the heater and the spa is shut
down. You must reset the message* when water is below 108°f (42.2°C).
Flow-Related Checks
Check for low water level, sucon flow restricons, closed valves, trapped air, too many closed jets and pump prime.
On some systems, even when spa is shut down by an error condion, some equipment may occasionally turn on to connue
monitoring temperature or if freeze protecon is needed.
* Some messages can be reset from the panel. Messages that can be reset will appear
with a Clear Icon at the boom of the Message Screen. Press the Clear Icon text to reset
the message.